izpis_h1_title_alt

Simultaneous analysis of ascorbic and dehydroascorbic acid in fruit juice using HILIC chromatography coupled with mass spectrometry : research data
ID Zia, Hassan (Avtor), ID Fischbach, Nadine (Avtor), ID Hofsommer, Mikko (Avtor), ID Slatnar, Ana (Avtor)

.docxDOCX - Opis podatkov, prenos (169,58 KB)
MD5: 25FA4D7E1C3F157A17E8D659C6221773
Opis: Brief description of data
.docxDOCX - Opis podatkov, prenos (49,62 KB)
MD5: FDED2A8925ACF687821EC759650D27FD
Opis: Figure, table
.xlsxXLSX - Raziskovalni podatki, prenos (56,61 KB)
MD5: EC1D40B1F9000ECF098B278BA54C46BA
To gradivo ima še več datotek. Celoten seznam je na voljo spodaj.

Izvleček
Method Development The most common technique for developing methods to analyze vitamins is an HPLC system coupled with a mass spectrometer (HPLC-MS). A triple quadrupole mass spectrometer operating under multiple reaction mode was used for analysis. At least two mass transitions per vitamin were selected and optimized for the corresponding ESI-MS/MS parameters. The details of the HPLC-MS/MS method can be found in the published articles. Method Validation According to the definition presented in ISO 5725, accuracy has two main components, trueness and precision, which must be assessed during the validation of an analytical method (International Organization for Standardization, 2020). These two characteristics can be evaluated holistically using the concept of accuracy profiles. The first step in method validation with accuracy profiles is deciding the acceptability limit (λ) which was set at 25 % in the current study. The following step is determining measurement uncertainty in the bias value at different concentration levels that cover the expected concentration range of target analytes (vitamins) in target samples (fruit juices). The data files summarizing validation results for different vitamins in different matrices (standard solution, strawberry nectar, and multifruit juice) are in Excel file format. They have three sheets inside each data file. The first three sheets contain the raw data from the different days the calibration or validation study was carried out. Please note that the concentrations are reported in µg/L, unless otherwise stated. Please refer to the coding scheme for samples in Figure 1 and Figure 2 for more details about the sample identity. Comparison of Technologies in Terms of Vitamin Retention The developed methods for B vitamins and vitamin C were used to determine the vitamin content in differently treated strawberry nectar (conventional thermal processing-TT, ohmic processing-OH, pulse electric field-PEF, high pressure processing-HPP). The analysis was done in triplicate.

Jezik:Angleški jezik
Ključne besede:HPLC–MS/MS, quality control, multifruit juice, ascorbic acid, dehydroascorbic acid, accuracy profile, validation
Organizacija:BF - Biotehniška fakulteta
Leto izida:2024
PID:20.500.12556/RUL-159568 Povezava se odpre v novem oknu
Metode zbir. podat.:Meritve in testi
Datum objave v RUL:12.07.2024
Število ogledov:9
Število prenosov:0
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Projekti

Financer:EC - European Commission
Program financ.:H2020
Številka projekta:956257
Naslov:Establishing a strong and lasting international training network for innovation in food and juice industries: a 4D-research approach for fruit juice processing
Akronim:HiStabJuice

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P4-0013
Naslov:Hortikultura

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Datoteke

Podatki se nalagajo...

Nazaj