izpis_h1_title_alt

Simultaneous analysis of ascorbic and dehydroascorbic acid in fruit juice using HILIC chromatography coupled with mass spectrometry : research data
ID Zia, Hassan (Author), ID Fischbach, Nadine (Author), ID Hofsommer, Mikko (Author), ID Slatnar, Ana (Author)

.docxDOCX - Data description, Download (169,58 KB)
MD5: 25FA4D7E1C3F157A17E8D659C6221773
Description: Brief description of data
.docxDOCX - Data description, Download (49,62 KB)
MD5: FDED2A8925ACF687821EC759650D27FD
Description: Figure, table
.xlsxXLSX - Research data, Download (56,61 KB)
MD5: EC1D40B1F9000ECF098B278BA54C46BA
This document has even more files. Complete list of files is available below.

Abstract
Method Development The most common technique for developing methods to analyze vitamins is an HPLC system coupled with a mass spectrometer (HPLC-MS). A triple quadrupole mass spectrometer operating under multiple reaction mode was used for analysis. At least two mass transitions per vitamin were selected and optimized for the corresponding ESI-MS/MS parameters. The details of the HPLC-MS/MS method can be found in the published articles. Method Validation According to the definition presented in ISO 5725, accuracy has two main components, trueness and precision, which must be assessed during the validation of an analytical method (International Organization for Standardization, 2020). These two characteristics can be evaluated holistically using the concept of accuracy profiles. The first step in method validation with accuracy profiles is deciding the acceptability limit (λ) which was set at 25 % in the current study. The following step is determining measurement uncertainty in the bias value at different concentration levels that cover the expected concentration range of target analytes (vitamins) in target samples (fruit juices). The data files summarizing validation results for different vitamins in different matrices (standard solution, strawberry nectar, and multifruit juice) are in Excel file format. They have three sheets inside each data file. The first three sheets contain the raw data from the different days the calibration or validation study was carried out. Please note that the concentrations are reported in µg/L, unless otherwise stated. Please refer to the coding scheme for samples in Figure 1 and Figure 2 for more details about the sample identity. Comparison of Technologies in Terms of Vitamin Retention The developed methods for B vitamins and vitamin C were used to determine the vitamin content in differently treated strawberry nectar (conventional thermal processing-TT, ohmic processing-OH, pulse electric field-PEF, high pressure processing-HPP). The analysis was done in triplicate.

Language:English
Keywords:HPLC–MS/MS, quality control, multifruit juice, ascorbic acid, dehydroascorbic acid, accuracy profile, validation
Organization:BF - Biotechnical Faculty
Year:2024
PID:20.500.12556/RUL-159568 This link opens in a new window
Data col. methods:Measurements and tests
Publication date in RUL:12.07.2024
Views:249
Downloads:33
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Projects

Funder:EC - European Commission
Funding programme:H2020
Project number:956257
Name:Establishing a strong and lasting international training network for innovation in food and juice industries: a 4D-research approach for fruit juice processing
Acronym:HiStabJuice

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P4-0013
Name:Hortikultura