Izvleček
Uvod: Ljudje smo vedno bolj izpostavljeni obstojnim in nevarnih kemikalijam, njihove negativne vplive na zdravje ljudi in živali ter tudi na okolje pa šele zdaj začenjamo razumeti. Kemikalije se zaradi sposobnosti bioakumulacije kopičijo v človeku ter ekosistemu. Ker so topne v vodi, se lahko distribuirajo po celotnem vodnem sistemu. Zaradi omenjenih razlogov je kemikalije potrebno hitro in učinkovito zaznavati. Za zaznavanje se trenutno najpogosteje uporabljajo različne analitske metode, ker pa so nekatere kemikalije v topilih težko obstojne, so te metode težko izvedljive. Obstojne in nevarne kemikalije analitsko najlažje določamo z uporabo kromatografije, med katere spada tudi kromatografija visoke ločljivosti. Glede na vrsto analita se tekom analiz lahko srečujemo z različnimi in številnimi parametri, ki lahko zapletejo proces. Za elektrokemijsko določanje kemikalij so razvite različne metode, ki se razvrščajo na podlagi agentov za prepoznavanje kemikalij. V zadnjih letih so veliko pozornosti pritegnili elektrokemijski senzorji, ki so v nasprotju z analitskimi metodami nizko cenovni, hitri, preprosti, enostavni ter tudi visoko občutljivi in majhni. Namen: Namen naloge je preučiti občutljivost analitske metode za določanje obstojnih in nevarnih kemikalij za spojine melamin, benzotriazol, bisfenol S in benzisothiazolinon ter preveriti občutljivost senzorjev za zaznavanje bisfenola S. Metode dela: Izvedli smo primerjavo analitske metode s pomočjo tekočinskega kromatografa visoke ločljivosti in treh različnih vrst elektrod za določanje nizkih koncentracij bisfenola S ter pripravili umeritvene krivulje za melamin, benzotriazol in benzisothiazolinon. Rezultati: S pomočjo tekočinskega kromatografa visoke ločljivosti smo zaznali koncentracije do 0,001 µM za benzotriazol ter še nižje koncentracije za ostale spojine. S pomočjo elektrokemijskih senzorjev smo za bisfenol S zaznali koncentracije le do 1 µM, kar pomeni, da lahko s pomočjo analitskih metod zaznamo nižje koncentracije kot s pomočjo elektrokemijskih metod. Razprava in zaključek: S pomočjo analitskih metod lahko zaznamo nižje koncentracije kot s pomočjo elektrokemijskih metod. Za izdelavo senzorjev bi bilo tako metode potrebno še modificirati, saj se v okolju nahajajo nizke koncentracije teh spojin. Za uporabo v senzorjih bi bile najbolj primerne komercialne sitotiskane elektrode, saj rezultati pri teh elektrodah najmanj variirajo, še vedno pa bi bila potrebna optimizacija metod.

Jezik:Slovenski jezik
Ključne besede:magistrska dela, sanitarno inženirstvo, obstojne in nevarne kemikalije, analitske metode, elektrokemijske metode, tekočinska kromatografija visoke ločljivosti, senzorji
Vrsta gradiva:Magistrsko delo/naloga
Tipologija:2.09 - Magistrsko delo
Organizacija:ZF - Zdravstvena fakulteta
Kraj izida:Ljubljana
Založnik:[Š. Črešnovar]
Leto izida:2023
Št. strani:64 str.
PID:20.500.12556/RUL-146360 Povezava se odpre v novem oknu
UDK:614
COBISS.SI-ID:154133763 Povezava se odpre v novem oknu
Datum objave v RUL:25.05.2023
Število ogledov:805
Število prenosov:122
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:The chromatographic methods for the determination of melamine, bisphenol S, benzotriazole and benzisothiazolinone and electrochemical method for the determination of bisphenol S : master thesis
Izvleček:
Introduction: Humans are increasingly exposed to persistent and dangerous chemicals, whose negative effects on human and animal health, as well as on the environment, are only now beginning to be understood. Because of their ability to bioaccumulate, they accumulate in humans and in the ecosystem. Because they are soluble in water, they can be distributed throughout the entire water system. For these reasons, rapid and efficient methods for detection of these chemicals is required. Analytical methods, of which there are several types, are currently the most widely used for the detection of these chemicals, but due to their persistence in the environment, these methods are difficult to implement. Persistent and dangerous chemicals are analytically determined most easily by using chromatography, which also includes the high pressure liquid chromatography. Depending on the type of analyte, during the analysis we may encounter various and even many parameters that can complicate the process. Various technologies have been developed for the electrochemical determination of these chemicals, classified according to chemical recognition agents. In recent years, electrochemical sensors have attracted a lot of attention, which, in contrast to analytical methods, are low-cost, fast, simple, easy, and also highly sensitive and small. Purpose: The aim is to examine the sensitivity of the analytical method for determining persistent and dangerous chemicals for the compounds melamine, bezotriazole, bisphenol s and benzisothiazolinone. And check the sensitivity of the sensors for detecting bisphenol S. Methods: A comparison of the analytical method using a high-resolution liquid chromatograph and three different types of electrodes for thedetermination of low concentrations of bisphenol S was carried out, as well as the performance of calibration curves for melamine, benzoriazole and benzisothiazolinone. Results: With the help of a high-resolution liquid chromatograph, we detected concentrations of up to 0.001 μM for benzotriazole and even lower concentrations for the other compounds. With the help of sensors, concentrations of bisphenol S were only as low as 1 μM. Which means that with the help of analytical methods we can detect lower concentrations than with the help of electrochemical methods. Discussion and conclusion: With the help of analytical methods, lower concentrations can be detected than with the help of electrochemical methods, which means that the methods would have to be modified in order to make sensors, since low concentrations of these compounds are found in the environment. For use in sensors, commercial screen printed electrodes would be the most suitable, since with these electrodes the results vary the least, but optimization of the methods would still be necessary.

Ključne besede:master's theses, sanitary engineering, persistent and dangerous chemicals, analytical methods, electrochemical methods, high pressure liquid chromatograph, sensors