izpis_h1_title_alt

Assessing spectral imaging of the human finger for detection of arthritis
ID Dolenec, Rok (Avtor), ID Laistler, Elmar (Avtor), ID Milanič, Matija (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (4,70 MB)
MD5: 96A501E867D8945EC023953809405E16
URLURL - Izvorni URL, za dostop obiščite https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-10-12-6555&id=423642 Povezava se odpre v novem oknu

Izvleček
Rheumatoid arthritis causes changes in the optical properties of tissues in the joints, which could be detected using spectral imaging. This has the potential for development of low cost, non-contact method for early detection of the disease. In this work, hyperspectral imaging system was used to obtain 24 images of proximal interphalangeal joints of 12 healthy volunteers. A large inter-subject variability was observed, but still an increase in transmittance in the spectral range of 600 nm – 950 nm could be associated to the joint in all images. The results of experiments were compared to detailed simulations of light propagation trough tissue. For the simulations, voxelized 3D models of unaffected and inflamed human joints with realistic tissue distributions were constructed from an in-vivo MRI scan of a healthy human finger. The simulated model of healthy finger successfully reproduced the experimental data, while the affected models indicated that the inflammation introduces detectable differences in the spectral and spatial features. The results were used to guide the design of a dedicated imaging system for detection of rheumatoid arthritis, that will be used in an upcoming clinical study.

Jezik:Angleški jezik
Ključne besede:medical physics, medical imaging, arthritis, optics
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FMF - Fakulteta za matematiko in fiziko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2019
Št. strani:Str. 6555-6568
Številčenje:Vol. 10, no. 12, art. 379114
PID:20.500.12556/RUL-128574 Povezava se odpre v novem oknu
UDK:616-073
ISSN pri članku:2156-7085
DOI:10.1364/BOE.10.006555 Povezava se odpre v novem oknu
COBISS.SI-ID:3386980 Povezava se odpre v novem oknu
Avtorske pravice:
V članku navedeno: "© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement"; s povezavo https://www.osapublishing.org/library/license_v1.cfm. (20. 7. 2021)
Datum objave v RUL:20.07.2021
Število ogledov:875
Število prenosov:193
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Biomedical optics express
Skrajšan naslov:Biomed. opt. express
Založnik:Optica
ISSN:2156-7085
COBISS.SI-ID:24857383 Povezava se odpre v novem oknu

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:medicinska fizika, medicinsko slikanje, artritis, optika

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:J2-8171
Naslov:Kombinirano multispektralno in termografsko slikanje za presejanje in spremljanje artritisa malih sklepov

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0389
Naslov:Medicinska fizika

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj