izpis_h1_title_alt

Ponovljivost in zanesljivost časovno merjenega "ulezi se in vstani" testa pri zdravih odraslih in povezanost izvedbe testa z antropometričnimi spremenljivkami : diplomsko delo
ID Arh, Gaber (Avtor), ID Jakovljević, Miroljub (Mentor) Več o mentorju... Povezava se odpre v novem oknu

.pdfPDF - Predstavitvena datoteka, prenos (1,13 MB)
MD5: 64DBF349E01B13317656A69710691E3A

Izvleček
Uvod: Časovno merjeni »ulezi se in vstani« test je bil zasnovan z namenom ugotavljanja funkcijske zmogljivosti zdravih odraslih. Namen: Namen diplomskega dela je bil ugotoviti ponovljivost in zanesljivost »ulezi se in vstani« testa pri zdravih odraslih preiskovancih ter ugotoviti povezanost izvedbe testa z antropometričnimi spremenljivkami. Metode: V raziskavo je bilo vključenih 30 prebivalcev Občine Bohinj, starih med 18 in 65 leti, med njimi 15 žensk in 15 moških. Test smo izvedli dvakrat z vmesnim 48-urnim premorom. Ponovljivost in zanesljivost testa smo izračunali s pomočjo intraklasnega korelacijskega koeficienta, standardne napake meritev ter najmanjše zaznane spremembe. Povezanost izvedbe testa z antropometričnimi spremenljivkami smo preverjali s Pearsonovim korelacijskim koeficientom. Rezultati: Povprečni čas treh ponovitev za izvedbo testa je znašal 4,7 sekunde v prvi seji in 4,9 sekunde v drugi seji. Ponovljivost je bila odlična, saj je intraklasni koeficient korelacije znašal 0,986 (IZ95% =0,975-0,993) v prvi seji in 0,990 (IZ95%=0,982-0,995) v drugi seji. Prav tako je bila odlična zanesljivost. Intaklasni koeficient korelacije je bil 0,989 (IZ95% =0,977-0,995). Standardna napaka merjenja je znašala 0,45 sekunde, najmanjša zaznana sprememba pa 1,24 sekunde. Ugotovili smo dobro povezanost izvedbe testa s starostjo preiskovancev in zmerno povezanost izvedbe testa z indeksom telesne mase in obsegom pasu preiskovancev. Sklep: »Ulezi se in vstani« test ima odlično ponovljivost in zanesljivost, zato ga priporočamo za ocenjevanje funkcijske zmogljivosti zdravih odraslih. Najprimernejši izračun izida je povprečje treh ponovitev. Potrebno bi bilo raziskati še veljavnost testa.

Jezik:Slovenski jezik
Ključne besede:funkcijsko testiranje, ponovljivost, zanesljivost, zdravi odrasli
Vrsta gradiva:Diplomsko delo/naloga
Organizacija:ZF - Zdravstvena fakulteta
Leto izida:2019
PID:20.500.12556/RUL-108493 Povezava se odpre v novem oknu
COBISS.SI-ID:5651051 Povezava se odpre v novem oknu
Datum objave v RUL:04.07.2019
Število ogledov:902
Število prenosov:150
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Repeatability and reliability of the timed "lay down-get up" test in healthy adults and the influence of anthropometric variables on performance of the test : diploma work
Izvleček:
Introduction: Timed “Lay down and get up” test was designed to evaluate functional capacity of healthy adults. Purpose: The purpose of the study was to determine repeatability and reliability of the timed »Lay down and get up« test in healthy adult subjects and to determine correlation between performance of the test with anthropometric variables. Methods: Thirty adults aged between 18 and 65 years (15 woman and 15 men) living in Bohinj municipality comprised the study sample. The test was performed twice with 48-hour break. Repeatability and reliability of the »Lay down and get up« test were calculated using intraclass correlation coefficient, standard error of measurement and the minimum detectable change. The correlation of the performance of the test with anthropometric variables was verified by Pearson's correlation coefficient. Results: The average time of three repetitions to perform the test was 4.7 seconds in the first session and 4.9 seconds in the second session. Repeatability was excellent, as the intraclass correlation coefficient was 0.986 (CI95%= 0,975-0,993) in the first session and 0.990 (CI95% = 0,982-0,995) in the second session. Reliability was excellent as well, as the intraclass correlation coefficient was 0.989 (CI95%= 0,977-0,995). Standard error of measurement was 0.45s and minimum detectable change was 1.24s. Good correlation was found between the performance of the test and the age of subjects and moderate correlation was found between the performance of the test and body mass index and the belt circumference of the subjects. Discussion and conclusion: »Lay down – get up« test is a clinical test with excellent repeatability and reliability. Therefore we recommend the test to evaluate functional capacity of healthy adults. The most appropriate calculation of the outcome is taking the average time of three repetitions into account. Validity still needs to be researched.

Ključne besede:functional testing, repeatabiliy, reliability, healthy adults