izpis_h1_title_alt

Eksperimentalno testiranje postopkov nanofiltracije poliamidamin-epiklorohidrinskih smol
ID Zwitter, Matej (Avtor), ID Golobič, Iztok (Mentor) Več o mentorju... Povezava se odpre v novem oknu

.pdfPDF - Predstavitvena datoteka, prenos (5,73 MB)
MD5: 00A0FD8E149DE6F5ECD692F169E79D4C
PID: 20.500.12556/rul/6cbd16cf-602a-4576-851a-3e22d6d08e0f

Izvleček
V nalogi obravnavamo diafiltracijo raztopine PAE smole z namenom zmanjšanja vsebnosti stranskih produktov DCP in MCPD. Uporabljeni sta nanofiltracijski membrani Koch SR3D in Koch SelRO MPS-34, obe s parametrom MWCO 200 daltonov. Spremljamo kratkoročno in dolgoročno spreminjanje permeabilnosti membran in stopnjo zadrževanja DCP in MCPD. Filtracija je izvajana pri nevtralnem pH. Rezultati kažejo, da skladno s pričakovanji PAE smola membran ne prehaja. V nasprotju s pričakovanji DCP in MCPD skozi membrano ne prehajata neovirano. Rezultati kažejo tudi, da se membrana tekom delovanja ne maši, maši pa se med mirovanjem naprave. Sprememba pH med čiščenjem tako v kislo, kot v bazično okolje prispeva k hitrejšemu mašenju membrane. Diskusija obravnava mehanizme zadrževanja DCP in MCPD ter mašenja membran.

Jezik:Slovenski jezik
Ključne besede:nanofiltracija, diafiltracija, PAE smola, mašenje membran, stopnja zadrževanja, efekt sita, hidrofobnost, površinski naboj, sprememba pH, mreženje polimerov
Vrsta gradiva:Magistrsko delo/naloga
Organizacija:FS - Fakulteta za strojništvo
Leto izida:2017
PID:20.500.12556/RUL-95551 Povezava se odpre v novem oknu
Datum objave v RUL:20.09.2017
Število ogledov:1493
Število prenosov:359
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Experimental testing of procedures for nanofiltration of polyamideamine-epichlorohydrin resins
Izvleček:
The paper deals with diafiltration of a solution of PAE resin, the purpose of which is to lower the concentration of residuals DCP and MCPD. Nanofiltration membranes Koch SR3D and Koch SelRO MPS-34, both with MWCO of 200 daltons are used. Short term an long term changes in permeability of membranes, as well as rejection of DCP and MCPD are recorded. Filtration is taking place at neutral pH. As expected, results show that PAE resin does not permeate through the membrane. More unexpected is the fact that DCP and MCPD do not permeate through the membrane freely. Results show there is no membrane fouling during the operation, but the membrane fouls when the device is stationary. Change of pH both towards the acidic, as well as caustic environment, contributes to faster membrane fouling. We discuss mechanisms of rejection of DCP and MCPD and mechanisms of membrane fouling.

Ključne besede:nanofiltration, diafiltration, PAE resin, membrane fouling, membrane rejection, sieving effect, hydrophobicity, surface charge, change of pH, polimer cross-linking

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj