Podrobno

Gama spektrometer na osnovi scintilacijskega pretvornika
ID LIKAR, MARKO (Avtor), ID Jankovec, Marko (Mentor) Več o mentorju... Povezava se odpre v novem oknu

.pdfPDF - Predstavitvena datoteka, prenos (3,98 MB)
MD5: 69F27BA2F8C4EE63C1578050F3194EC7
PID: 20.500.12556/rul/a9dc2b1e-5d29-4b9e-be16-716db76c1037

Izvleček
Običajno nas pri meritvah sevanja zanima ne samo aktivnost, ampak tudi energija nekega neznanega ionizirajočega sevanja. Zato sem se namenil izdelati instrument, ki bo lahko meril poleg jakosti tudi energijski spekter γ žarkov. Na koncu, ko je bil instrument skupaj s programom na mikrokrmilniku končan, sem lahko opravil še meritve nihanja visoke napetosti, doseg instrumenta od najnižje možne energije pa do najvišje, ki jo lahko še merimo, ločljivost pri določenih energijah in linearnost izmerjenega energijskega spektra. Izkazalo se je, da instrument ponuja kljub nekaj ubranim bližnjicam dobro ločljivost. Pri merjenju izotopa K-40, s sevalno energijo γ sevanja 1460 keV, ima instrument 5.3 % ločljivost. Kar je primerljivo z drugimi merilniki, ki so na voljo te čase na tržišču. Žal pa zaradi zmanjšanja porabe visokonapetostnega dela ima za skoraj 3.6 % slabšo linearnost, ki na vgrajenem prikazovalniku ni opazna. Za natančnejše meritve na računalniku pa je nelinearnost prevelika.

Jezik:Slovenski jezik
Ključne besede:Gama spektrometer, scintilator, fotopomnoževalka, tiskano vezje
Vrsta gradiva:Diplomsko delo/naloga
Organizacija:FE - Fakulteta za elektrotehniko
Leto izida:2014
PID:20.500.12556/RUL-30040 Povezava se odpre v novem oknu
Datum objave v RUL:13.11.2014
Število ogledov:2424
Število prenosov:680
Metapodatki:XML DC-XML DC-RDF
:
LIKAR, MARKO, 2014, Gama spektrometer na osnovi scintilacijskega pretvornika [na spletu]. Diplomsko delo. [Dostopano 18 maj 2025]. Pridobljeno s: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=slv&id=30040
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Gamma spectrometer based on a scintillation converter
Izvleček:
Generally when measuring radiation we are interested not only in intensity but in energy of unknown ionising radiation too. For this purpose I committed myself to built such instrument that will be capable of measuring intensity and energy spectrum of γ radiation. At the end when the instrument was finished together with the program on microcontroller, we were able to measure fluctuation of high voltage supply, energy range of the instrument, linearity and resolution at specified energy. Despite of some shortcuts taken, the measured resolution at 1460 keV from K-40 radioactive element was 5.3 %. Which is very good and comparable to other such instrument nowadays on the market. But on the other hand because of lowering the power consumption of high voltage supply, the linearity is very poor, measured 3.6 %. Which is not visible on the built in LCD, but for more precise measurements on computer it is too high.

Ključne besede:Gamma spectrometer, scintillator, photomultiplier tube, printed circuit

Podobna dela

Podobna dela v RUL:
  1. Prototip scintilacijskega detektorja za merjenje uhajanja pri izolirani perfuziji udov
  2. Karakterizacija fotopomnoževalke v nasičenem režimu s simulatorjem scintilacijskih bliskov
  3. Optimizacija scintilacijskega detektorja BGO za detektorski sistem DEGAS
  4. RAZVOJ IN IZDELAVA PRENOSNE SLEDILNE NAPRAVE
  5. Nadgradnja študijskega pozitronskega tomografa
Podobna dela v drugih slovenskih zbirkah:
  1. Izvedba močnostnega modula vzporednega trifaznega pretvornika
  2. Development of the photomultiplier tube readout system for the first Large-Sized Telescope of the Cherenkov Telescope Array
  3. Kompakten optični osciloskop
  4. Avtonomno aktivno breme za testiranje baterij
  5. Development of the photomultiplier-tube readout system for the CTA Large Size Telescope

Nazaj