Surface-guided versus conventional setup in rectal cancer radiotherapy : a workflow-level comparison of CBCT-Derived setup corrections
ID
Žager Marciuš, Valerija
(
Avtor
),
ID
Boshkovski, Petar
(
Avtor
),
ID
Danevska, Mila
(
Avtor
),
ID
Salmič, Klemen
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(772,31 KB)
MD5: 00BF60D4571DD89261971AD351B83D9F
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S0969804326005051
Galerija slik
Izvleček
Background: Precise patient positioning is essential in rectal cancer radiotherapy to ensure target coverage while protecting organs at risk. Surface-guided radiotherapy (SGRT) is a non-invasive setup method that may improve accuracy and reduce repeat imaging. This study compared SGRT-based positioning with conventional tattoobased setup. Methods: This retrospective analysis included 100 rectal cancer patients treated with Volumetric Modulated Arc Therapy on Varian linear accelerator: TrueBeam (SGRT-guided positioning) and Halcyon (manual Delta couch positioning). Translational shifts from CBCT verification were analysed across all axes, and additional CBCT imaging at matched fractions was compared (p ≤ 0.05). Results: Mean translational corrections were numerically larger on the Halcyon in five of six directions, but none of the six between-accelerator comparisons remained statistically significant after correction (corrected p ≥ 0.744; effect size r ≤ 0.15). Within accelerators, TrueBeam corrections were symmetric across all three axes, whereas the Halcyon showed a significant left–right asymmetry (p = 0.031). At least one additional CBCT scan was required in 48% of Halcyon patients versus 18% of TrueBeam patients (p = 0.001), and the mean number of additional scans was more than seven times higher on the Halcyon (1.40 vs 0.18; p < 0.001), driven mainly by bladder and rectal filling rather than gross positional error. Conclusion: Translational setup accuracy was comparable between workflows, but Halcyon patients required substantially more repeat CBCT imaging, suggesting that SGRT's main benefit lies in reducing imaging burden rather than improving geometric accuracy.
Jezik:
Angleški jezik
Ključne besede:
image-guided radiotherapy
,
patient positioning
,
patient setup accuracy
,
rectal cancer
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
ZF - Zdravstvena fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Datum objave:
01.12.2026
Leto izida:
2026
Št. strani:
7 str.
Številčenje:
Vol. 238, art. 112921
PID:
20.500.12556/RUL-191626
UDK:
615.82/.84
ISSN pri članku:
0969-8043
DOI:
10.1016/j.apradiso.2026.112921
COBISS.SI-ID:
291753475
Datum objave v RUL:
24.11.2026
Število ogledov:
11
Število prenosov:
5
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Applied radiation and isotopes
Skrajšan naslov:
Appl. radiat. isotopes
Založnik:
Pergamon
ISSN:
0969-8043
COBISS.SI-ID:
1039892
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj