Primerjalna analiza meritev prstana Senstream Research Ring pri razlicnih telesnih aktivnostih
ID Rožič, Jakob (Avtor), ID Geršak, Gregor (Avtor), ID Stanić, Valentina (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (479,78 KB)
MD5: DB0849FF06465C358E5A102FD36B6C3E
URLURL - Izvorni URL, za dostop obiščite https://erk.fe.uni-lj.si/2026/papers/rozic(primerjalna_analiza).pdf Povezava se odpre v novem oknu

Jezik:Slovenski jezik
Ključne besede:nosljivi merilniki, prevodnost kože, elektrodermalna aktivnost, artefakt gibanja
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Leto izida:2026
Št. strani:Str. 683-686
UDK:621.317
ISSN pri članku:2591-0442
COBISS.SI-ID:294181891 Povezava se odpre v novem oknu
Datum objave v RUL:05.11.2026
Število ogledov:30
Število prenosov:1
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del zbornika

Naslov:Zbornik petintridesete mednarodne Elektrotehniške in računalniške konference ERK 2026
COBISS.SI-ID:292311811 Povezava se odpre v novem oknu

Gradivo je del revije

Naslov:Zbornik ... mednarodne Elektrotehniške in računalniške konference
Založnik:Slovenska sekcija IEEE, Fakulteta za elektrotehniko
ISSN:2591-0442
COBISS.SI-ID:291620352 Povezava se odpre v novem oknu

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Comparative analysis of senstream research ring measurements across different physical activities
Izvleček:
The paper compares three systems for measuring electrodermal activity (EDA) under static and dynamic conditions: the BIOPAC MP150 with the EDA100C module, the wireless BIOPAC BioNomadix BN-PPGED system, and the wearable Senstream Research Ring. The aim was to evaluate how different electrode concepts, mechanical designs, and attachment methods affect the recorded skin conductance signal during rest, walking, and running. A repeated single-subject protocol was performed three times, with all three systems used simultaneously in each repetition. Signals were processed in Python using NeuroKit2, and the tonic skin conductance level (SCL), detected skin conductance response (SCR) peaks, SCL changes relative to rest, and Pearson correlations of tonic trends were analysed. The systems differed in absolute SCL values, signal stability, and sensitivity to motion. EDA100C detected a very high number of SCR peaks during running, indicating strong sensitivity to motion-related disturbances. The Senstream Research Ring showed lower absolute SCL values but a smoother tonic trend and greater temporal similarity to EDA100C than BioNomadix. This similarity reflects the time course of the tonic signal and does not by itself confirm measurement accuracy during movement.

Ključne besede:wearables, skin conductance, electrodermal actvitiy, motion artefacts