Podrobno

Meritev časovne ločljivosti zaznave posameznega fotona matrike SiPM z vezjem FastIC+
ID Perko, Tina (Avtor), ID Trost, Andrej (Avtor), ID Zadnik, Damjan (Avtor), ID Žemva, Andrej (Avtor), ID Seljak, Andrej (Avtor), ID Dolenec, Rok (Avtor), ID Pestotnik, Rok (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,96 MB)
MD5: 64B8048C1680A6476DDB3914C75C56AF
URLURL - Izvorni URL, za dostop obiščite https://erk.fe.uni-lj.si/2026/papers/perko(meritev_casovne).pdf Povezava se odpre v novem oknu

Jezik:Slovenski jezik
Ključne besede:pozitronska emisijska tomografija, časovna ločljivost posameznega fotona, SPTR, silicijeva fotopomnoževalka, večkanalni sistem za odčitavanje
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Leto izida:2026
Št. strani:Str. 12-17
UDK:621.38
ISSN pri članku:2591-0442
COBISS.SI-ID:293171971 Povezava se odpre v novem oknu
Datum objave v RUL:05.11.2026
Število ogledov:69
Število prenosov:31
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del zbornika

Naslov:Zbornik petintridesete mednarodne Elektrotehniške in računalniške konference ERK 2026
COBISS.SI-ID:292311811 Povezava se odpre v novem oknu

Gradivo je del revije

Naslov:Zbornik ... mednarodne Elektrotehniške in računalniške konference
Založnik:Slovenska sekcija IEEE, Fakulteta za elektrotehniko
ISSN:2591-0442
COBISS.SI-ID:291620352 Povezava se odpre v novem oknu

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Measurement of the single-photon time resolution of a SiPM array using the FastIC+ ASIC
Izvleček:
This paper presents single-photon time resolution (SPTR) measurements for eight elements of the Broadcom AFBR-S4N44P164M silicon photomultiplier (SiPM) array, each read out through a separate channel of the FastIC+ application-specific integrated circuit (ASIC). Measurements were performed with one, two, four, and eight SiPM elements simultaneously illuminated and the corresponding FastIC+ channels read out. Single-photon events were selected using energy information from the linear energy chain, and the SPTR was determined as the full width at half maximum of a Gaussian fit to the timing histogram. The mean SPTR across the eight channels increased from 133.3±3.3 ps in single-channel operation to 145.6 ± 3.7 ps with two active channels, while only minor additional changes were observed with four and eight active channels, for which values of 145.4 ± 3.9 ps and 147.7 ± 5.4 ps were obtained, respectively. The reported standard deviations describe the spread among the mean SPTR values of the individual channels. Individual channels differed both in their single-channel SPTR and in their sensitivity to multichannel operation. The results show that single-channel characterization alone does not fully describe the timing performance of a multichannel SiPM readout system.

Ključne besede:positron emission tomography, single-photon time resolution, SPTR, silicon photomultiplier, multichannel readout

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj