Podrobno

Eksperimentalna primerjava termografskih fosforjev za merjenje temperature na osnovi luminiscencnega upada
ID Semelbauer, Klemen (Avtor), ID Mlačnik, Vid (Avtor), ID Pušnik, Igor (Avtor), ID Beguš, Samo (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (2,81 MB)
MD5: E59FF2564B6C403E9717209C07882CA4
URLURL - Izvorni URL, za dostop obiščite https://erk.fe.uni-lj.si/2026/papers/semelbauer(eksperimentalna_primerjava).pdf Povezava se odpre v novem oknu

Jezik:Slovenski jezik
Ključne besede:termografski fosfor, čas upada, merjenje temperature
Tipologija:1.08 - Objavljeni znanstveni prispevek na konferenci
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Leto izida:2026
Št. strani:Str. 353-356
PID:20.500.12556/RUL-190820 Povezava se odpre v novem oknu
UDK:621.317
ISSN pri članku:2591-0442
COBISS.SI-ID:293090819 Povezava se odpre v novem oknu
Datum objave v RUL:04.11.2026
Število ogledov:24
Število prenosov:3
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del zbornika

Naslov:Zbornik petintridesete mednarodne Elektrotehniške in računalniške konference ERK 2026
COBISS.SI-ID:292311811 Povezava se odpre v novem oknu

Gradivo je del revije

Naslov:Zbornik ... mednarodne Elektrotehniške in računalniške konference
Založnik:Slovenska sekcija IEEE, Fakulteta za elektrotehniko
ISSN:2591-0442
COBISS.SI-ID:291620352 Povezava se odpre v novem oknu

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Experimental comparison of thermographic phosphors for temperature measurement based on luminescence decay
Izvleček:
Four thermographic phosphors, QMK24/N-C7, QMK66/F-A1, MK24/F-X and EQD25/F-U1, were applied to brass substrates using an inorganic Ceramabind 643-2 binder. A thin brush coating and a syringe-applied coating were compared. The samples were spectrally characterized under 405 nm and 365 nm excitation and tested in an automated dual-channel phosphor-thermometry system with detection near 635 nm and 660 nm. Only QMK24/N-C7 and EQD25/F-U1 provided a sufficient signalto-noise ratio for stable exponential fitting at several temperatures. Values digitized from the recorded plots indicate sensitivities from −15, 6 to −20, 1 µs/ ◦C for QMK24/N-C7 and from −7, 8 to −8, 4 µs/ ◦C for EQD25/FU1. QMK24/N-C7 was nominally more sensitive, while EQD25/F-U1 produced higher SNR and therefore more repeatable temperature characteristics. The results show that spectral matching, coating thickness and coating homogeneity must be considered together when selecting a phosphor for a practical measurement system.

Ključne besede:thermographic phosphor, decay time, temperature measurement

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj