Podrobno

The influence of slope calculation method on the reliability of near-infrared spectroscopy parameters during a vascular occlusion test : research data underlying the article
ID Iskra, Simon (Avtor), ID Turnšek, Gašper (Avtor), ID Paravlić, Armin (Avtor)

.txtTXT - Opis podatkov. Vsebina dokumenta nedostopna do 06.01.2027.
MD5: A87AA43DCEEBE6939E27A0489C8B5F97
Opis: README
.xlsxXLSX - Raziskovalni podatki. Vsebina dokumenta nedostopna do 06.01.2027.
MD5: B1C7C4A35CF9B6D9E353E1CC12C7A870
Opis: Data NIRSVOT

Izvleček
Aim: To assess within and between-day reliability of near-infrared spectroscopy derived measures of microvascular function during a vascular occlusion test (VOT), to assess whether different methods for slope calculation and blood volume correction improve reliability. Methods: Twenty-three healthy adults (11 males, 12 females) completed three laboratory visits, during which a VOT was performed using a continuous-wave NIRS device on the forearm. Reoxygenation (reoxyslope) and deoxygenation (deoxyslope) slopes along with muscle oxygen uptake (mVO2) were calculated using a fixed 10-s average, as well as maximal 3- and 1-s rolling averages for reoxygenation and average, 30-s and 10-s rolling average for deoxygenation parameters. Additionally, mVO2 was corrected for blood volume change (mVO2corr). Intraclass correlation coefficients were used to determine the within- and between-day reliability of selected measures. Results: There were no differences in within- or between-day reliability for different methods of calculation of selected parameters. However, significantly higher values were observed when shorter time window was used. In general, the parameters exhibited moderate to good within- and poor to moderate between-day reliability. Blood volume correction improved reliability of mVO2 values. Linear mixed model analysis revealed sex as a significant predictor of reoxyslope and mVO2corr, with males exhibiting slower reoxyslope and higher mVO2corr. Conclusion: The slope calculation method significantly influences the values obtained during VOT, while their reliability remains unchanged. The use of a blood volume correction is warranted and data quality reporting in future studies seems warranted. Significant sex differences were observed, highlighting the different mechanism regulating microvascular function during VOT.

Jezik:Angleški jezik
Ključne besede:near-infrared spectroscopy, vascular occlusion test, reliability, microvascular reactivity
Tipologija:2.20 - Zaključena znanstvena zbirka raziskovalnih podatkov
Organizacija:FŠ - Fakulteta za šport
Leto izida:2026
PID:20.500.12556/RUL-188022 Povezava se odpre v novem oknu
Metode zbir. podat.:Poskus
Datum objave v RUL:17.09.2026
Število ogledov:20
Število prenosov:0
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:bližnje infrardeča spektroskopija, test žilne okluzije, zanesljivost, mikrovaskularna reaktivnost

Projekti

Financer:University of Ljubljana Development Fund
Številka projekta:005–1/2023
Naslov:The role of physical Activity in Cardiovascular disease risk reducTiOn for Non-communicable diseases. Do non-responders to exercise really exist?

Financer:University of Ljubljana Development Fund
Številka projekta:802–15/2023–5
Naslov:The role of physical Activity in Cardiovascular disease risk reducTiON – On the way to personalized exercise prescription
Akronim:ACT-ON

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P5-0147
Naslov:Kineziologija monostrukturnih, polistrukturnih in konvencionalnih športov

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj