Podrobno

Two-year outcomes of tissue-level and bone-level two-piece zirconia implants : a case series
ID Žarković Gjurin, Sonja (Avtor), ID Povšič, Katja (Avtor), ID Kobe, Tom (Avtor), ID Žužek, Borut (Avtor), ID Gašperšič, Rok (Avtor), ID Oblak, Čedomir (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,42 MB)
MD5: D42988EF7AF523CA902FED5D2E543E5C
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2673-6373/6/1/1 Povezava se odpre v novem oknu

Izvleček
Background/objectives: Zirconia dental implants are increasingly recognised as an alternative to titanium implants due to their biocompatibility and aesthetics. Initially developed as one-piece systems, zirconia implants have evolved into two-piece designs with different platform levels; however, comparative data on their primary and secondary stability– particularly as assessed by resonance frequency analysis (RFA)—and marginal bone dynamics remain limited. This case series aimed to evaluate the implant stability and marginal bone changes of two-piece zirconia implants with bone-level (BL) and tissue-level (TL) platforms in patients missing maxillary premolars. Methods: Thirteen zirconia implants (n = 13; 7 BL, 6 TL; Z5-TL/Z5-BL, Z-Systems, Switzerland) were placed in 11 patients with healed ridges. The implant stability quotient (ISQ) was measured immediately after insertion and before prosthetic loading. Lithium disilicate crowns were cemented after four months, and follow-ups were conducted for an average of 35 months (SD = 12). Results: Initial ISQ values ranged from 73 to 79, increasing to 76–84 at 3–4 months, indicating high implant stability for both BL and TL implants. The extent of marginal bone loss (MBL) after two years was greater around BL implants (mean 0.46 mm) compared to TL implants (mean 0.2 mm), although probing depths and bleeding on probing remained minimal in both groups, with only one TL implant showing gingival recession. Conclusions: Over a short observation period, two-piece zirconia implants with tissue-level platforms appeared to demonstrate superior marginal tissue stability. Further, larger-scale controlled studies are required to confirm these preliminary observations.

Jezik:Angleški jezik
Ključne besede:zirconia implants, ceramic, two-piece, bone-level, tissue-level, implant stability, ISQ
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2026
Št. strani:12 str.
Številčenje:Vol. 6, iss. 1
PID:20.500.12556/RUL-185472 Povezava se odpre v novem oknu
UDK:616.31
ISSN pri članku:2673-6373
DOI:10.3390/oral6010001 Povezava se odpre v novem oknu
COBISS.SI-ID:264750083 Povezava se odpre v novem oknu
Datum objave v RUL:06.08.2026
Število ogledov:168
Število prenosov:57
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Oral
Skrajšan naslov:Oral
Založnik:MDPI
ISSN:2673-6373
COBISS.SI-ID:80648451 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:cirkonijevi vsadki, keramika, dvodelni, na ravni kosti, na ravni tkiva, stabilnost vsadka

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj