Optic nerve sheath diameter increases during 12° head-down tilt in healthy volunteers : a crossover pilot study informing the design of a spaceflight countermeasure trial
ID
Bergauer, Andrej
(
Avtor
),
ID
Urevc, Janez
(
Avtor
),
ID
Steuber, Bianca
(
Avtor
),
ID
Schimd-Zalaudek, Karin
(
Avtor
),
ID
Pivec, Vid
(
Avtor
),
ID
Goswami, Nandu
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(1,14 MB)
MD5: 268DEB8C52465A7272A2E95B43381D41
URL - Izvorni URL, za dostop obiščite
https://www.frontiersin.org/journals/physiology/articles/10.3389/fphys.2026.1890637/full
Galerija slik
Izvleček
Background: Spaceflight-associated neuro-ocular syndrome (SANS) is hypothesized to arise from a headward fluid shift that elevates intracranial pressure and distends the optic nerve sheath. Head-down tilt (HDT) is the ground-based analog of microgravity, and optic nerve sheath diameter (ONSD) measured by transorbital B-mode ultrasound is a candidate non-invasive marker of intracranial pressure. Before a definitive trial in which lower body negative pressure (LBNP) is added to 12° HDT as a putative countermeasure, we conducted a pilot study to (i) confirm that 12° HDT detectably elevates ONSD with a high-frequency linear probe, (ii) identify the time of peak response, (iii) optimize the measurement schedule, and (iv) provide effect-size estimates for powering.Methods: Eight healthy young participants (4 women, 4 men; mean age 30.9 years) underwent two conditions in a randomized, balanced two-period crossover with a 14-day washout: supine (0° HDT) and 12° HDT. Bilateral transorbital B-mode ultrasound was recorded with a 17-MHz linear probe (Philips iU22) at 0, 30, 60, 90, 120, 150, 180, 210 and 240 min. Five frames per clip were measured offline and averaged across both eyes. The primary analysis was a 2-way repeated-measures ANOVA (Condition × Time) with Greenhouse–Geisser correction. Posthoc paired comparisons at each time point used Bonferroni adjustment. Gender was examined in a secondary mixed model.Results: The Condition × Time interaction was highly significant (pGG< 0.001). ONSD did not differ between conditions up to 60 min but was larger under 12° HDT from 90 min onward, peaking at 150 min with a mean increment of 0.79 mm (95% CI 0.62–0.97), then partially regressing. No gender effect was detected, and baseline ONSD did not differ between visits, consistent with adequate washout.Conclusion: A 12° HDT exposure of ≥ 90 min produces a reproducible, large-magnitude ONSD increase peaking at 150 min in healthy adults; a 0–180 min measurement window is sufficient. These data support a full three-arm crossover trial of LBNP as a candidate countermeasure, with graduated lower-limb compression included as a mechanistic positive control to verify that headward fluid redistribution is the aggravating factor.
Jezik:
Angleški jezik
Ključne besede:
crossover design
,
head-down tilt
,
intracranial pressure
,
ONSD
,
optic nerve sheath diameter
,
SANS
,
spaceflight-associated neuro-ocular syndrome
,
transorbital ultrasound
,
microgravity
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
FS - Fakulteta za strojništvo
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2026
Št. strani:
9 str.
Številčenje:
Vol. 17, art. 1890637
PID:
20.500.12556/RUL-185358
UDK:
531.5:617.78
ISSN pri članku:
1664-042X
DOI:
10.3389/fphys.2026.1890637
COBISS.SI-ID:
286611715
Datum objave v RUL:
31.07.2026
Število ogledov:
213
Število prenosov:
66
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Frontiers in physiology
Skrajšan naslov:
Front. physiol.
Založnik:
Frontiers Research Foundation
ISSN:
1664-042X
COBISS.SI-ID:
1218939
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
nagib z glavo navzdol
,
intrakranialni tlak
,
premer ovojnice vidnega živca
,
nevrookularni sindrom
,
transorbitalna ultrasonografija
,
mikrogravitacija
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj