Validity and reliability of two strain gauges to measure upper-body relative strength in gymnastics still rings
ID Lecocq, Tom (Avtor), ID Mochizuki, Luis (Avtor), ID Gouelle, Arnaud (Avtor), ID Tordi, Nicolas (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,11 MB)
MD5: 447BD04BF66623D3919921EA06BCD8C5
URLURL - Izvorni URL, za dostop obiščite https://journals.uni-lj.si/sgj/article/view/19084 Povezava se odpre v novem oknu

Izvleček
The still rings routine has evolved over the last century, emphasizing increasing strength. What is paramount is not absolute but relative strength, as each gymnast hangs from the still rings and must overcome the effect of gravity on their body using their own upper limb characteristics: strength and dimension. While the vertical force produced by the gymnast is easily measured on a force plate, a specific computation is required when the force is measured in the cable, as the cables are not perfectly vertical. No publication has yet investigated the impact of cable length or the distance between the rings (i.e., the gymnast's arm span) on the tension measured in the cable. The purpose of this study is to validate strain gauges in comparison with a force plate and to provide recommendations for their use in assessing a gymnast's relative strength. To address this, a static loading procedure was performed with weights ranging from 50 to 80 kg, increasing in increments of 10 kg (50, 60, 70, 80 kg). Different distances between the still rings were tested, ranging from 50 cm (vertical cables – 0.0° angle) to 170 cm (31.1° angle), with increments of 20 cm (i.e., 10 cm on each side). Each weight was first placed on a pair of force plates (K-Deltas, Kinvent Biomécanique) before being hung in the middle of the rings with cables equipped with 1-axis strain gauges (K-Pull traction dynamometers, Kinvent Biomécanique). The largest discrepancy between the two methods was 10.31 N, which could be attributed to the sensor as well as the distance between the rings. This article provides a clear answer to the questions regarding the effects of the angle and the length of the cable on tension. Strain gauges are a smaller, lighter, and more affordable alternative to force plates while remaining reliable, valid, and discriminative, provided that the cable angle is known.

Jezik:Angleški jezik
Ključne besede:sport, gymnastics, mechanics, force, tension, angle, gymnastics still rings
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FŠ - Fakulteta za šport
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:Str. 139-151, 161
Številčenje:Vol. 17, iss. 1
PID:20.500.12556/RUL-183705 Povezava se odpre v novem oknu
UDK:796.41
ISSN pri članku:1855-7171
DOI:10.52165/sgj.17.1.139-151 Povezava se odpre v novem oknu
COBISS.SI-ID:230902531 Povezava se odpre v novem oknu
Avtorske pravice:
Podatek o licenci CC BY-SA 4.0 je naveden na pristajalni strani članka (glej zgoraj izvorni URL). (Datum opombe: 19. 6. 2026)
Datum objave v RUL:19.06.2026
Število ogledov:203
Število prenosov:159
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Science of gymnastics journal
Založnik:University of Ljubljana Press, Slovenia (Založba Univerze v Ljubljani)
ISSN:1855-7171
COBISS.SI-ID:246418176 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-SA 4.0, Creative Commons Priznanje avtorstva-Deljenje pod enakimi pogoji 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-sa/4.0/deed.sl
Opis:Ta licenca Creative Commons je zelo podobna običajni licenci Priznanje avtorstva, vendar zahteva, da so materialne avtorske pravice na izpeljanih delih upravljane z enako licenco.

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Veljavnost in zanesljivost dveh namestitev za merenje relativne moči zgornjega dela telesa na telovadnih krogih
Izvleček:
Sestava na doskočnih krogih se je razvijala skozi preteklo stoletje, pri čemer je bil poudarek na povečevanju moči. Ključna ni absolutna, temveč sorazmerna moč, saj mora vsak telovadec v vesi na krogih premagati učinek težnosti na svoje telo z uporabo značilnosti svojih zgornjih okončin: moči in razsežnosti. Medtem ko je navpična sila, ki jo telovadec proizvaja, enostavno merljiva na pritiskovni plošči, je za natančno merjenje sile v jeklenici potrebna posebna izračunava, saj jeklenice niso popolnoma navpične. Nobena raziskava doslej ni preučila vpliva dolžine jeklenice ali razdalje med krogi (tj. razpona rok telovadca) na napetost, merjeno v jeklenici. Namen te raziskave je preveriti natančnost merilnikov napetosti v primerjavi s pritiskovno ploščo in ponuditi priporočila za njihovo uporabo pri ocenjevanju sorazmerne moči telovadca. Za to je bil izveden statičen obremenitveni postopek z utežmi, ki so znašale od 50 do 80 kg, s povečevanjem po 10 kg (50, 60, 70, 80 kg). Testirane so bile različne razdalje med krogi, od 50 cm (navpične jeklenice – kot 0,0°) do 170 cm (kot 31,1°), z večanjem po 20 cm (tj. 10 cm na vsaki strani). Vsaka utež je bila najprej postavljena na par pritiskovnih plošč (K-Deltas, Kinvent Biomécanique), preden je bila obešena na sredino krogov z jeklenicami, opremljenimi z enosmernimi merilniki napetosti (K-Pull vlečni dinamometri, Kinvent Biomécanique). Največja odstopanja med obema načinoma je bila 10,31 N, kar bi lahko pripisali čitalcu ter razdalji med krogi. Ta članek ponuja jasen odgovor na vprašanja glede učinkov kota in dolžine jeklenice na napetost. Merilniki napetosti so manjša, lažja in cenovno ugodnejša zamenjava pritiskovnim ploščam, pri čemer ostajajo zanesljivi, veljavni in razlikovalni, če je kot jeklenice znan.

Ključne besede:šport, gimnastika, telovadba, mehanika, sila, napetost, kot, telovadni krogi

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Zbirka

To gradivo je del naslednjih zbirk del:
  1. Science of gymnastics journal

Nazaj