Podrobno

Impact of pectoral muscle removal on deep-learning-based breast cancer risk prediction
ID Klaneček, Žan (Avtor), ID Wang, Yao Kuan (Avtor), ID Wagner, Tobias (Avtor), ID Cockmartin, Lesley (Avtor), ID Marshall, Nicholas (Avtor), ID Schott, Brayden (Avtor), ID Deatsch, Alison (Avtor), ID Studen, Andrej (Avtor), ID Jarm, Katja (Avtor), ID Krajc, Mateja (Avtor), ID Vrhovec, Miloš (Avtor), ID Bosmans, Hilde (Avtor), ID Jeraj, Robert (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (5,62 MB)
MD5: 68418E36D574579170953A534DC2A64F
URLURL - Izvorni URL, za dostop obiščite https://iopscience.iop.org/article/10.1088/1361-6560/adb367 Povezava se odpre v novem oknu

Izvleček
Objective. State-of-the-art breast cancer risk (BCR) prediction models have been originally trained on mammograms with pectoral muscle (PM) included. This study investigated whether excluding PM during training/fine-tuning improves the model’s BCR discrimination performance, calibration, and robustness. Approach. First, the Original deep learning model (MIRAI), trained on the US (Massachusetts General Hospital) data, was validated, and the relative contribution of PM to BCR predictions was evaluated using saliency maps. Additionally, 23 792 mammograms from the Slovenian screening program were collected and two datasets were created, with and without screening positive exams. The original MIRAI was then fine-tuned on the training/fine-tuning set of Slovenian mammograms with and without PM, creating Fine-tuned MIRAI models. In total, four models (Original MIRAI with PM, Original MIRAI without PM, Fine-tuned MIRAI with PM, Fine-tuned MIRAI without PM) were compared on a test set in terms of discrimination performance for 1–5 Year BCR (evaluating area under the curve), calibration performance (measured with expected calibration error—ECE) and robustness to incremental PM removals/additions, and to incremental breast tissue removals. Results. The relative contribution of PM to the BCR prediction on the Original MIRAI model was low (∼5%); however, there were significant outliers where the relative contribution was more than 50%. The removal of PM did not impact the 1–5 Year BCR discrimination performance of the Original MIRAI (with screening positive exams: 0.77–0.91, without screening positive exams: 0.64–0.67). Fine-tuned MIRAI on mammograms with PM removed achieved significantly higher 1-5 Year BCR discrimination performance (with screening positive exams: 0.82–0.93, without screening positive exams: 0.71–0.79). After recalibration, all models had similar ECE (with screening positive exams: 0.04–0.05, without screening positive exams: 0.02–0.03). Significance. Improved BCR discrimination performance can be achieved when the model is trained/fine-tuned on mammograms with PM removed.

Jezik:Angleški jezik
Ključne besede:breast cancer risk, calibration, mammography, pectoral muscle, deep learning, convolutional neural networks, robustness
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FMF - Fakulteta za matematiko in fiziko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:19 str.
Številčenje:Vol. 70, no. 5, art. 055006
PID:20.500.12556/RUL-178236 Povezava se odpre v novem oknu
UDK:614
ISSN pri članku:0031-9155
DOI:10.1088/1361-6560/adb367 Povezava se odpre v novem oknu
COBISS.SI-ID:226342403 Povezava se odpre v novem oknu
Datum objave v RUL:21.01.2026
Število ogledov:608
Število prenosov:255
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Physics in medicine & biology
Skrajšan naslov:Phys. med. biol.
Založnik:IOP Publishing, Institute of Physics and Engineering in Medicine
ISSN:0031-9155
COBISS.SI-ID:26128896 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:dejavniki tveganja, rak dojke, kalibracija, mamografija

Projekti

Financer:Research Foundation—Flanders
Številka projekta:G0A7121N

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P1-0389
Naslov:Medicinska fizika

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj