Podrobno

Eliminating seasonal energy storage needs through envelope design : real-world cost analysis of quadruple glazing in office buildings
ID Kralj, Aleš (Avtor), ID Kurnitski, Jarek (Avtor), ID Žnidaršič, Matjaž (Avtor), ID Medved, Sašo (Avtor), ID Domjan, Suzana (Avtor), ID Halilovič, Miroslav (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (4,18 MB)
MD5: 2B91C6D2AD1E24F225F0945E024F2999
URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S2213138825005181 Povezava se odpre v novem oknu

Izvleček
Space-heating peaks and associated seasonal storage needs remain the bottleneck for zero-emission buildings; windows are pivotal because their thermal losses set winter demand. This study’s objective is to quantify the energy, peak-load, and life-cycle-cost (LCC) impacts of argon-filled quadruple glazing (QGU) relative to triple (TGU) and quintuple (5GU) units, and to derive a climate-robust and energy price level criterion for adoption. We coupled multilayer window models to a dynamic simulation (IDA ICE) of an office floor in two climates (Ljubljana, Oslo) across four native SHGC levels, then performed a 30-year LCC analysis using observed manufacturing prices, gross-margin assumptions, and electricity-price scenarios; we mapped cost-parity as a function of heating-degree-days (HDD). QGU systematically reduced delivered heating energy and peak heating power versus TGU, with a small cooling increase, yielding LCC parity in colder conditions at observed prices and margins; in milder climates, parity depended on higher electricity prices or lower margins. The research con- tributes (i) the first LCC assessment of commercially manufactured argon-filled QGU grounded in measured pricing and dynamic simulation, and (ii) an HDD-based adoption criterion that links envelope choice to lower winter peaks and reduced seasonal storage requirements without added life-cycle cost, offering guidance for high-WWR design and envelope policy.

Jezik:Angleški jezik
Ključne besede:life-cycle cost analysis, quadruple glazing, zero-emission buildings
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2025
Št. strani:9 str.
Številčenje:Vol. 84, [article no.] 104687
PID:20.500.12556/RUL-175883 Povezava se odpre v novem oknu
UDK:621
ISSN pri članku:2213-1396
DOI:10.1016/j.seta.2025.104687 Povezava se odpre v novem oknu
COBISS.SI-ID:256920067 Povezava se odpre v novem oknu
Datum objave v RUL:12.11.2025
Število ogledov:117
Število prenosov:21
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Sustainable energy technologies and assessments
Založnik:Elsevier
ISSN:2213-1396
COBISS.SI-ID:175448579 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:analiza stroškov življenjskega cikla, štirislojna zasteklitev, stavbe z ničelnimi emisijami

Projekti

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:L2-3172
Naslov:Razvoj tehničnih smernic za štirislojne zasteklitve

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P2-0263
Naslov:Mehanika v tehniki

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P2-0223
Naslov:Prenos toplote in snovi

Financer:Drugi - Drug financer ali več financerjev
Številka projekta:TK230