vOARiability : interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images
ID Podobnik, Gašper (Avtor), ID Ibragimov, Bulat (Avtor), ID Peterlin, Primož (Avtor), ID Strojan, Primož (Avtor), ID Vrtovec, Tomaž (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (6,19 MB)
MD5: C8F9738DA0CFB483FEF6C1C70BD372D7
URLURL - Izvorni URL, za dostop obiščite https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.16924 Povezava se odpre v novem oknu

Izvleček
Background Accurate and consistent contouring of organs-at-risk (OARs) from medical images is a key step of radiotherapy (RT) cancer treatment planning. Most contouring approaches rely on computed tomography (CT) images, but the integration of complementary magnetic resonance (MR) modality is highly recommended, especially from the perspective of OAR contouring, synthetic CT and MR image generation for MR-only RT, and MR-guided RT. Although MR has been recognized as valuable for contouring OARs in the head and neck (HaN) region, the accuracy and consistency of the resulting contours have not been yet objectively evaluated. Purpose To analyze the interobserver and intermodality variability in contouring OARs in the HaN region, performed by observers with different level of experience from CT and MR images of the same patients. Methods In the final cohort of 27 CT and MR images of the same patients, contours of up to 31 OARs were obtained by a radiation oncology resident (junior observer, JO) and a board-certified radiation oncologist (senior observer, SO). The resulting contours were then evaluated in terms of interobserver variability, characterized as the agreement among different observers (JO and SO) when contouring OARs in a selected modality (CT or MR), and intermodality variability, characterized as the agreement among different modalities (CT and MR) when OARs were contoured by a selected observer (JO or SO), both by the Dice coefficient (DC) and 95-percentile Hausdorff distance (▫$HD_95$▫). Results The mean (±standard deviation) interobserver variability was 69.0 ± 20.2% and 5.1 ± 4.1 mm, while the mean intermodality variability was 61.6 ± 19.0% and 6.1 ± 4.3 mm in terms of DC and ▫$HD_95$▫, respectively, across all OARs. Statistically significant differences were only found for specific OARs. The performed MR to CT image registration resulted in a mean target registration error of 1.7 ± 0.5 mm, which was considered as valid for the analysis of intermodality variability. Conclusions The contouring variability was, in general, similar for both image modalities, and experience did not considerably affect the contouring performance. However, the results indicate that an OAR is difficult to contour regardless of whether it is contoured in the CT or MR image, and that observer experience may be an important factor for OARs that are deemed difficult to contour. Several of the differences in the resulting variability can be also attributed to adherence to guidelines, especially for OARs with poor visibility or without distinctive boundaries in either CT or MR images. Although considerable contouring differences were observed for specific OARs, it can be concluded that almost all OARs can be contoured with a similar degree of variability in either the CT or MR modality, which works in favor of MR images from the perspective of MR-only and MR-guided RT.

Jezik:Angleški jezik
Ključne besede:variability analysis, contouring, organs-at-risk, computed tomography, magnetic resonance, radiotherapy, head and neck cancer
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:Str. 2175-2186
Številčenje:Vol. 51, no. 3
PID:20.500.12556/RUL-173359 Povezava se odpre v novem oknu
UDK:004.93
ISSN pri članku:0094-2405
DOI:10.1002/mp.16924 Povezava se odpre v novem oknu
COBISS.SI-ID:181670147 Povezava se odpre v novem oknu
Datum objave v RUL:16.09.2025
Število ogledov:169
Število prenosov:72
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Medical physics
Skrajšan naslov:Med. phys.
Založnik:American Institute of Physics
ISSN:0094-2405
COBISS.SI-ID:25924096 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:analiza variabilnosti, orisovanje, kritični organi, računalniška tomografija, magnetna resonanca, radioterapija, rak glave in vrat

Projekti

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:J2-1732
Naslov:Računalniško podprta analiza medicinskih slik za načrtovanje zdravljenja s protonsko in radioterapijo

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P2-0232
Naslov:Analiza biomedicinskih slik in signalov

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P3-0307
Naslov:Rak glave in vratu - analiza bioloških značilnosti in poskus izboljšanja zdravljenja

Financer:Novo Nordisk Foundation
Številka projekta:NFF20OC0062056
Naslov:Leveraging artificial intelligence for pancreatic cancer diagnosis, treatment planning and treatment outcome prediction

Financer:Institute of Oncology Ljubljana
Številka projekta:ERID-EK/139

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj