Comparison of anteroposterior and posteroanterior projection in erect pelvic radiography
ID
Hajdarević, Amir
(
Avtor
),
ID
Mekiš, Nejc
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(792,69 KB)
MD5: 8BA7BB6BDD92980D49D8D0CF306CA66C
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S0969804325002040
Galerija slik
Izvleček
Purpose: The X-ray examination of the pelvis is one of the procedures with the highest radiation dose and the most common X-ray examination. For this reason, this study investigated whether the alternative posteroanterior (PA) projection can be used instead of the established anteroposterior (AP) projection to perform pelvic radiography in an erect position. Methods: The study was conducted in a clinical setting on 100 patients who were referred to erect pelvic radiography. The patients were randomly divided into two equal groups of 50; the first group was imaged in the AP projection, and the second group in the PA projection. Weight and height were measured for each patient, from which the body mass index was calculated. During imaging, the source-to-patient was measured, and the tube voltage, tube current and time product, Dose Area Product (DAP), source-to-image receptor distance, and primary field size were collated. Based on these data, the entrance surface dose (ESD) and the effective dose, as well as the dose to selected organs, were calculated. In addition to measured dosimetric values, image quality was also assessed by three experienced radiologists using ViewDEX 2.57 software. Results: No statistically significant differences were found between the AP and PA projection of erect pelvic radiography for DAP and ESD. On the other hand, a statistically significant difference of 51.5 % (p < 0.001) was found when comparing the effective dose. There were no statistically significant differences between the image quality of the radiographs taken in the PA in AP projection. Conclusion: Based on the above results, we can conclude that PA projection should be the method of choice when performing an erect pelvic radiography due to a significant decrease in effective dose.
Jezik:
Angleški jezik
Ključne besede:
pelvic radiography
,
dose reduction
,
image quality
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
ZF - Zdravstvena fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2025
Št. strani:
6 str.
Številčenje:
Vol. 222, art. 111859
PID:
20.500.12556/RUL-169047
UDK:
616-07
ISSN pri članku:
1872-9800
DOI:
10.1016/j.apradiso.2025.111859
COBISS.SI-ID:
235212803
Datum objave v RUL:
08.05.2025
Število ogledov:
68
Število prenosov:
14
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Applied radiation and isotopes
Založnik:
Elsevier
ISSN:
1872-9800
COBISS.SI-ID:
23195141
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj