Podrobno

Comparison of increase in masticatory efficiency between removable partial dentures retained with clasps and retained with attachments
ID Dula, Linda J. (Avtor), ID Shala, Kujtim Sh. (Avtor), ID Štubljar, David (Avtor), ID Starc, Andrej (Avtor), ID Kosumi, Shera (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (470,64 KB)
MD5: A6433324E1D1A36560EEF5DB61888DC7
URLURL - Izvorni URL, za dostop obiščite https://onlinelibrary.wiley.com/doi/10.1002/cre2.70130 Povezava se odpre v novem oknu

Izvleček
Objectives: This study aimed to evaluate and compare the masticatory efficiency of removable partial dentures (RPDs) retained with clasps versus those retained with attachments. Material and Methods: A total of 107 patients fitted with 138 RPDs participated in the study; 87 RPDs (63.0%) were clasp‐retained, and 51 RPDs (37.0%) were attachment‐retained. Subjects chewed 5.0 g of peanuts for 30 s, and masticatory efficiency was measured using a spectrophotometer at an absorption rate of 590 µm. Measurements were taken before insertion, immediately after, and 1 and 3 months post‐insertion of RPDs. Results: The analysis revealed progressive masticatory efficiency improvements for both clasp‐retained and attachment‐retained RPDs over time, with significant enhancements observed at the 3‐month post‐insertion mark. Initially, clasp-retained RPDs showed slightly higher efficiency than attachment‐retained RPDs; however, attachment‐retained RPDs demonstrated superior efficiency after 3 months (p = 0.001). Consistent improvements were noted across different denture support types, with Triangular and Quadrangular supports showing the most notable gains by 3 months (p ≤ 0.006). GLMM analysis underscored the significant impact of time on masticatory efficiency (F(3, 511) = 4.926, p = 0.002), with no significant effects attributed to RPD type or support type alone, nor any significant interaction effects, indicating a universal improvement in masticatory function over time regardless of RPD design. Conclusions: RPD insertion significantly improves masticatory efficiency, particularly evident 3 months post‐insertion, with attachment-retained RPDs outperforming clasp‐retained types. Improvements in masticatory function over time are consistent across all RPD designs, unaffected by denture type or support structure. This emphasizes the role of denture design in both immediate adaptation and long‐term treatment success, suggesting that time significantly contributes to enhanced masticatory efficiency regardless of RPD design, highlighting the importance of tailored prosthetic rehabilitation.

Jezik:Angleški jezik
Ključne besede:removable partial dentures, masticatory efficiency, attachment clasp
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:ZF - Zdravstvena fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Datum objave:01.01.2025
Leto izida:2025
Št. strani:11 str.
Številčenje:Vol. 11, iss. 2, art. e70130
PID:20.500.12556/RUL-168745 Povezava se odpre v novem oknu
UDK:616.31
ISSN pri članku:2057-4347
DOI:10.1002/cre2.70130 Povezava se odpre v novem oknu
COBISS.SI-ID:233520131 Povezava se odpre v novem oknu
Datum objave v RUL:23.04.2025
Število ogledov:268
Število prenosov:151
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Clinical and experimental dental research
Skrajšan naslov:Clin. exp. dent. res.
Založnik:Wiley
ISSN:2057-4347
COBISS.SI-ID:525818905 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj