Non-invasive and continuous intra-abdominal pressure assessment using MC sensors
ID
Plešnik, Boštjan
(
Avtor
),
ID
Djokić, Mihajlo
(
Avtor
),
ID
Djordjević, Srdjan
(
Avtor
),
ID
Krašna, Simon
(
Avtor
),
ID
Žumer, Jan
(
Avtor
),
ID
Trotovšek, Blaž
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(1,40 MB)
MD5: 4655E1E1A9782C4E9104113974CBFE14
URL - Izvorni URL, za dostop obiščite
https://www.nature.com/articles/s41598-025-95512-x
Galerija slik
Izvleček
Monitoring intra-abdominal pressure (IAP) in critical care patients is crucial for preventing intra- abdominal hypertension (IAH) and abdominal compartment syndrome (ACS), with their severe consequences. The muscle contraction sensor (MC) introduced in this study offers a novel, non-invasive method with promising accuracy based on previous findings. This study further evaluates the MC accuracy and reproducibility and examines its correlation with objective IAP measurements obtained through a ▫$CO_2$▫ insufflator. We enrolled 41 patients undergoing elective laparoscopic gallbladder removal under general anesthesia with complete muscle relaxation. Two MC sensors were placed on the right and left sides of the abdomen, and elevated IAP was induced by insufflating ▫$CO_2$▫ into the peritoneal cavity. IAP measurements from the MC sensors were compared to the randomized IAP values set on the ▫$CO_2$▫ insufflator. Data from both methods were analyzed to assess the accuracy and agreement with the insufflator measurements. The MC sensor provided continuous and accurate detection of IAP changes. A Pearson correlation coefficient of 0.963 indicated a strong positive linear correlation between the MC sensor readings and the IAP values set on the insufflator. The coefficient of determination (▫$R^2$▫) was 0.927, showing that the model explains 92.7% of the variation in IAP values based on the MC sensor signals. Receiver operating characteristic analysis demonstrated that the MC sensor system performed exceptionally well in identifying both IAH and ACS cases, with an area under the curve of 0.996 for IAH and 0.981 for ACS. The study introduces a transcutaneous pressure measuring device as an innovative, non-invasive method for assessing IAP. The system strongly correlates with IAP values measured by ▫$CO_2$▫ insufflation, indicating its accuracy. It thus could present an alternative to conventional IAP measurement in the future. The MC capability to deliver real-time, continuous data holds substantial potential for proactive patient care. By incorporating advanced analytics like machine learning, the system could detect trends and provide early warnings of dangerous IAP changes, enabling timely, targeted interventions to enhance outcomes for critically ill patients.
Jezik:
Angleški jezik
Ključne besede:
intra-abdominal pressure
,
transcutaneous sensor
,
non-invasive measurement
,
abdominal compartment syndrome
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
FS - Fakulteta za strojništvo
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2025
Št. strani:
9 str.
Številčenje:
Vol. 15, art. 10775
PID:
20.500.12556/RUL-168206
UDK:
612:621
ISSN pri članku:
2045-2322
DOI:
10.1038/s41598-025-95512-x
COBISS.SI-ID:
231194371
Datum objave v RUL:
02.04.2025
Število ogledov:
431
Število prenosov:
118
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Scientific reports
Skrajšan naslov:
Sci. rep.
Založnik:
Nature Publishing Group
ISSN:
2045-2322
COBISS.SI-ID:
18727432
Licence
Licenca:
CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:
Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
intra-abdominalni tlak
,
transkutani senzor
,
neinvazivna meritev
,
utesnitveni sindrom trebuha
Projekti
Financer:
ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:
P2-0109-2018
Naslov:
Modeliranje v tehniki in medicini
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj