Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Least squares approach to standard platinum resistance thermometer subrange inconsistency reduction with redundant gallium and indium fixed points
ID
Žužek, Vincencij
(
Avtor
),
ID
Rusby, Richard
(
Avtor
),
ID
Pearce, Jonathan
(
Avtor
),
ID
Peruzzi, Andrea
(
Avtor
),
ID
Bojkovski, Jovan
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(2,66 MB)
MD5: 34EC4A81CFB7040E4B965B7EAF86C3F3
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S0263224123009648
Galerija slik
Izvleček
The International Temperature Scale of 1990 (ITS-90) defines several different and sometimes overlapping temperature subranges. Where overlap occurs, different definitions of the temperature t$_{90}$ exist that have equal status but produce different results. This discrepancy is called type 1 non-uniqueness or subrange inconsistency (SRI). In this paper, the SRI of the water-aluminum/water-zinc (SRI(Al:Zn)) and of the water-zinc/water-tin (SRI(Zn:Sn)) subranges of the ITS-90 were investigated for three cases. In the first case, the calculations followed the ITS-90 prescribed procedure. In the second case, the SPRT was calibrated at all fixed points of the subrange and its deviation function was then determined using the least squares method. In the third case, the least squares method was weighted by the uncertainties at each of the fixed points. One benefit of the least squares approach over exact interpolation is the reduction in uncertainty propagated from the fixed points. The calculations were applied to a large ensemble of 30 different SPRTs from the database of the Laboratory of Metrology and Quality at the University of Ljubljana, Slovenia. The sample consisted mainly of SPRTs manufactured by Fluke, Rosemount and AccuMac. The difference in the mean and standard deviation of SRI(Al:Zn) for the three cases was small, amounting to less than 0.06 mK. On the other hand, the mean of SRI(Zn:Sn) decreased from 0.73 mK to 0.01 mK and the standard deviation decreased from 1.25 mK to 0.43 mK when the weighted least squares approach was applied. Furthermore, the total propagated uncertainty from the fixed points decreased in particular temperature ranges with weighted least squares, especially from 50 °C to 300 °C (by about 50% compared to the ITS-90 case) and to a lesser extent from 400 °C to 600 °C (by about 10% compared to the ITS-90 case). The contribution of the difference in the uncertainty propagation between pairs of subranges to SRI was estimated to be at least 50% in all cases. According to the presented results, it can be advantageous to calibrate the SPRT at all available fixed points in the selected temperature subrange and then determine its deviation function using the weighted least squares method.
Jezik:
Angleški jezik
Ključne besede:
standard platinum resistance thermometer
,
SPRT
,
subrange inconsistency
,
SRI
,
non-uniqueness
,
International Temperature Scale of 1990
,
ITS-90
,
polynomial least squares
,
propagation of uncertainty
,
PoU
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
FE - Fakulteta za elektrotehniko
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2023
Št. strani:
7 str.
Številčenje:
Vol. 220, art. 113400
PID:
20.500.12556/RUL-153052
UDK:
006.91
ISSN pri članku:
0263-2241
DOI:
10.1016/j.measurement.2023.113400
COBISS.SI-ID:
167928067
Datum objave v RUL:
15.12.2023
Število ogledov:
777
Število prenosov:
38
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Measurement : journal of the International Measurement Confederation
Skrajšan naslov:
Measurement
Založnik:
Elsevier, International Measurement Confederation
ISSN:
0263-2241
COBISS.SI-ID:
25917696
Licence
Licenca:
CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:
Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
standardni platinasti uporovni termometer
,
neskladnost podobmočij
,
Mednarodna temperaturna lestvica iz leta 1990
,
metoda najmanjših kvadratov
,
končna negotovost
Projekti
Financer:
EC - European Commission
Program financ.:
H2020
Akronim:
EMPIR
Financer:
Drugi - Drug financer ali več financerjev
Program financ.:
EMPIR
Številka projekta:
18SIB02
Naslov:
Realizing the redefined kelvin
Financer:
Drugi - Drug financer ali več financerjev
Program financ.:
Ministry of Economic Development and Technology, Metrology Institute of the Republic of Slovenia
Številka projekta:
6401-18/2008/70
Financer:
ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:
J2-1721
Naslov:
Nova generacija industrijskih šumnih termometrov
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj