izpis_h1_title_alt

Intra-rater reliability of the knee arthrometer GNRB® for measuring knee anterior laxity in healthy, active subjects
ID Magdič, Miha (Avtor), ID Gošnak Dahmane, Raja (Avtor), ID Vauhnik, Renata (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (1,03 MB)
MD5: 80152576B1E7E83F98417675F250F9DA
URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S0972978X23000715 Povezava se odpre v novem oknu

Izvleček
Background: Arthrometers are used to assess knee anterior laxity and to evaluate the integrity of the anterior cruciate ligament. Assessment of knee anterior laxity is crucial part of the clinical examination. The aim of this study was to investigate the intra-rater reliability of the GNRB® in healthy subjects. Methods: In the study participated 97 subjects and two measurements using a GNRB® arthrometer were performed. Males were tested two times one week a part. Females were tested two times within 24 h. Measurements were performed at the following forces 134 N, 134 N, 150 N, 200 N, and 200 N. To evaluate the reliability of GNRB® measurements an intraclass correlation coefficient was calculated. Results: Intra-rater reliability of the GNRB® measurements is good for 134 N on the left knee (ICC = 0.848) and the right knee (ICC = 0.788) and for 200 N on the left knee (ICC = 0.805) and the right knee (ICC = 0.756). Conclusion: The GNRB® knee arthrometer has good intra-reliability for measurements at the 134 N and 200 N forces. Reliability can be increased with the standardize position of the subject, the stabilization of the patella and standardize measurement protocol.

Jezik:Angleški jezik
Ključne besede:GNRB® arthrometer, reliability, knee anterior laxity, anterior cruciate ligament, knee injury
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:ZF - Zdravstvena fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2023
Št. strani:Str. 7-10
Številčenje:Vol. 39
PID:20.500.12556/RUL-145108 Povezava se odpre v novem oknu
UDK:615.8:617.3
ISSN pri članku:0972-978X
DOI:10.1016/j.jor.2023.03.016 Povezava se odpre v novem oknu
COBISS.SI-ID:147970307 Povezava se odpre v novem oknu
Datum objave v RUL:06.04.2023
Število ogledov:564
Število prenosov:127
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Journal of orthopaedics (online)
Skrajšan naslov:J. orthop.
Založnik:Elsevier, Professor P K Surendran Memorial Education Foundation
ISSN:0972-978X
COBISS.SI-ID:519702297 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:GNRB® artrometer, zanesljivost, sprednja ohlapnost kolena, sprednja križna vez, poškodba kolena

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P3-0388
Naslov:Mehanizmi varovanja zdravja

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj