izpis_h1_title_alt

Pre-oxidation of selective-laser-melted titanium dental alloy : effects on surface characteristics and porcelain bonding
ID Antanasova, Maja (Avtor), ID Kocjan, Andraž (Avtor), ID Abram, Anže (Avtor), ID Kovač, Janez (Avtor), ID Jevnikar, Arne Peter (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (2,60 MB)
MD5: 5C5114D6A8683792654BED8EFEED6134
URLURL - Izvorni URL, za dostop obiščite https://www.tandfonline.com/doi/full/10.1080/01694243.2021.1877003 Povezava se odpre v novem oknu

Izvleček
The heat treatment of dental alloys prior to porcelain application/veneering has been proposed as a way to ensure sufficient oxide scale and to promote the porcelain's adherence in porcelain-fused-to-metal (PFM) fixed dental prostheses. The present study investigates the relationship between the bond strength of the dental porcelain to selective-laser-melted (SLM) titanium and the temperature of the titanium's pre-oxidation. The SLM Ti-6Al-4V substrates were airborne-particle abraded and either left to passivate in air at room temperature (control) or pre-oxidized in a furnace under vacuum conditions (10kPa) at temperatures of 300, 600, 750, or 800 °C. The surface characteristics were determined using contact profilometry to measure the profile roughness (R$_a$), atomic force microscopy for the surface roughness (S$_a$) and Auger electron spectroscopy for the thickness of the oxide scale. Dental porcelain was applied to the metal substrates and the titanium-ceramic bond was assessed according to the ISO standard 9693-1:2012. The metal-ceramic interfaces were analyzed with scanning electron microscopy and energy-dispersive spectroscopy. The R$_a$ and S$_a$ values showed a strong positive correlation with the pre-oxidation temperature. The oxide scales covering the titanium surfaces thickened markedly at temperatures of 750 °C and above. However, the bond strength was negatively correlated with the pre-oxidation temperature. Room-temperature passivation in air following the airborne-particle abrasion of the SLM titanium resulted in a titanium-ceramic bond that is well above the ISO 9693-1:2012 recommended minimum value for metal-ceramic systems. Thus, no pre-oxidation of SLM titanium frameworks is necessary prior to the application/firing of porcelain.

Jezik:Angleški jezik
Ključne besede:prosthetic dentistry, bond strength, titanium, metal-ceramic, selective laser melting
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2021
Št. strani:Str. 2094-2109
Številčenje:Vol. 35, no. 19
PID:20.500.12556/RUL-141219 Povezava se odpre v novem oknu
UDK:616.31
ISSN pri članku:0169-4243
DOI:10.1080/01694243.2021.1877003 Povezava se odpre v novem oknu
COBISS.SI-ID:50192131 Povezava se odpre v novem oknu
Datum objave v RUL:26.09.2022
Število ogledov:396
Število prenosov:43
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Journal of adhesion science and technology
Skrajšan naslov:J. adhes. sci. technol.
Založnik:Taylor & Francis
ISSN:0169-4243
COBISS.SI-ID:34942720 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:protetično zobozdravstvo, trdnost vezi, titan

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0087
Naslov:Keramični in komplementarni materiali za napredne inženirske in biomedicinske aplikacije