Stress-free measurement of body temperature of pigs by using thermal imaging : useful fact or wishful thinking
ID
Štukelj, Marina
(
Avtor
),
ID
Hajdinjak, Melita
(
Avtor
),
ID
Pušnik, Igor
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(13,31 MB)
MD5: 6E60C9D0ED8326BA39F38C38EC163D96
URL - Izvorni URL, za dostop obiščite
https://www.sciencedirect.com/science/article/pii/S0168169921006736
Galerija slik
Izvleček
Growing concern regarding animal welfare has increased the need for reliable methods of assessing the animal health status without stress during commercial farm practice. Measuring the body temperature with a thermal imaging camera is one possible stress-free technique since it is non-contact and non-invasive. The first objective of this study was to determine the best anatomical site in healthy pigs for measuring the temperature with a high spatial resolution thermal imaging camera that gives results equivalent or related to the temperatures measured in the rectum. The second objective was the assessment of the possibility to accurately and reliably measure or predict the pigs’ temperature with a low spatial resolution thermal imaging camera. Reference temperatures, measured with a calibrated thermometer in the rectum, were compared to the measurements of two calibrated thermal imaging cameras (a low resolution camera and a high resolution camera) on four anatomical sites of pigs (ear canal, eye canthus, outer ear and perianal area). We found that it is not possible to accurately measure or predict the pigs’ body temperature with a high noise equivalent temperature difference (NETD), low accuracy, low spatial resolution thermal imaging camera. However, a low NETD, high accuracy, high spatial resolution thermal imaging camera gives at least results that enable prediction (using a linear regression model) of the pigs’ body temperature. We showed that there are three anatomical sites in healthy pigs (ear canal, outer ear, perianal area) that are statistically similarly suitable for predicting the body temperature with a calibrated high spatial resolution thermal imaging camera under non diseased thermal neutral conditions.
Jezik:
Angleški jezik
Ključne besede:
animal welfare
,
infra-red thermography
,
measurement site
,
pigs
,
rectal temperature
,
statistical regression
,
body temperature
,
thermometry
Vrsta gradiva:
Članek v reviji
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
VF - Veterinarska fakulteta
FE - Fakulteta za elektrotehniko
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2022
Št. strani:
14 str.
Številčenje:
Vol. 193, art. 106656
PID:
20.500.12556/RUL-139085
UDK:
636.09:621.317
ISSN pri članku:
1872-7107
DOI:
10.1016/j.compag.2021.106656
COBISS.SI-ID:
93839363
Datum objave v RUL:
30.08.2022
Število ogledov:
657
Število prenosov:
142
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Computers and electronics in agriculture
Založnik:
Elsevier
ISSN:
1872-7107
COBISS.SI-ID:
23219205
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Projekti
Financer:
ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:
V4-1604
Naslov:
Dobrobit v povezavi z zdravstvenim varstvom perutnine ter prašičev v konvencionalnih in alternativnih sistemih rej
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj