izpis_h1_title_alt

Measurements of air quality in kindergartens and schools in the Republic of Slovenia before the COVID-19 epidemic
ID Muhič, Simon (Avtor), ID Muhič, Tatjana (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (3,06 MB)
MD5: 66FFF65010BA4A51157CFA8928D5E2F8
URLURL - Izvorni URL, za dostop obiščite https://ojs30.sv-jme.eu/index.php/sv-jme/article/view/13/25 Povezava se odpre v novem oknu

Izvleček
This article presents measurements of air quality in school and kindergarten facilities, which were carried out in 311 spaces throughout the Republic of Slovenia, before taking measures to improve energy efficiency of measured buildings. During the measurements, the internal dimensions of the spaces were also measured, as well as data on the energy efficiency of buildings and weather data at the time of the measurements. The measurements focused on indoor carbon dioxide concentration levels and air temperature and relative humidity of indoor air. The performed statistical analysis of measurements shows a large dispersion of measured parameters in buildings, which cannot be statistically significantly related to the analyzed quantities. During the occupancy of the spaces, a statistically significant difference in the concentration of carbon dioxide in the indoor air between the spaces of schools and kindergartens was found. The results of the measurements were also evaluated from the point of view of the COVID-19 pandemic. The average value of measured carbon dioxide value during occupancy of the spaces was compared with the results of a model that predicts an airborne transmission risk. The measured average value of relative humidity in kindergartens shows that relative humidity was 37 %, where is the highest infection risk according to recent studies. The measured average carbon dioxide concentration in classrooms and playrooms significantly exceeds the safe concentration, predicted by the model, to prevent COVID-19 spread at the expected six-hour exposure.

Jezik:Angleški jezik
Ključne besede:natural ventilation, carbon dioxide monitoring, COVID-19, indoor air quality, schools, kindergartens
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Datum objave:01.04.2022
Leto izida:2022
Št. strani:Str. 290-299
Številčenje:Vol. 68, no. 4, spec. iss.: SARS-Cov-2
PID:20.500.12556/RUL-136394 Povezava se odpre v novem oknu
UDK:697
ISSN pri članku:2536-3948
DOI:10.5545/sv-jme.2022.13 Povezava se odpre v novem oknu
COBISS.SI-ID:105850371 Povezava se odpre v novem oknu
Datum objave v RUL:28.04.2022
Število ogledov:845
Število prenosov:80
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Strojniški vestnik
Skrajšan naslov:Stroj. vestn.
Založnik:Fakulteta za strojništvo
ISSN:2536-3948
COBISS.SI-ID:294943232 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:18.01.2022
Vezano na:Accepted for publication

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Meritve kakovosti zraka v prostorih vrtcev in šol v Republiki Sloveniji pred epidemijo COVID-19
Ključne besede:naravno prezračevanje, meritve koncentracije ogljikovega dioksida, COVID-19, kakovost zraka v prostorih, šole, vrtci

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj