izpis_h1_title_alt

Assessing velocity and directionality of uterine electrical activity for preterm birth prediction using EHG surface records
ID Jager, Franc (Avtor), ID Geršak, Ksenija (Avtor), ID Vouk, Paula (Avtor), ID Pirnar, Žiga (Avtor), ID Trojner-Bregar, Andreja (Avtor), ID Lučovnik, Miha (Avtor), ID Borovac, Ana (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (9,23 MB)
MD5: 92C5C4D19CC3BA1CCF06C1F0F19C227D
URLURL - Izvorni URL, za dostop obiščite https://www.mdpi.com/1424-8220/20/24/7328 Povezava se odpre v novem oknu

Izvleček
The aim of the present study was to assess the capability of conduction velocity amplitudes and directions of propagation of electrohysterogram (EHG) waves to better distinguish between preterm and term EHG surface records. Using short-time cross-correlation between pairs of bipolar EHG signals (upper and lower, left and right), the conduction velocities and their directions were estimated using preterm and term EHG records of the publicly available Term–Preterm EHG DataSet with Tocogram (TPEHGT DS) and for different frequency bands below and above 1.0 Hz, where contractions and the influence of the maternal heart rate on the uterus, respectively, are expected. No significant or preferred continuous direction of propagation was found in any of the non-contraction (dummy) or contraction intervals; however, on average, a significantly lower percentage of velocity vectors was found in the vertical direction, and significantly higher in the horizontal direction, for preterm dummy intervals above 1.0 Hz. The newly defined features—the percentages of velocities in the vertical and horizontal directions, in combination with the sample entropy of the EHG signal recorded in the vertical direction, obtained from dummy intervals above 1.0 Hz—showed the highest classification accuracy of 86.8% (AUC = 90.3%) in distinguishing between preterm and term EHG records of the TPEHGT DS.

Jezik:Angleški jezik
Ključne besede:propagation of EHG waves, cross correlation, dummy intervals, contraction intervals, conduction velocity, preterm birth prediction, electrohysterogram, short-time cross-correlation, conduction velocity directionality
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FRI - Fakulteta za računalništvo in informatiko
MF - Medicinska fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2020
Št. strani:30 str.
Številčenje:Vol. 20, iss. 24, art. 7328
PID:20.500.12556/RUL-134660 Povezava se odpre v novem oknu
UDK:004:616.831-073.7-71
ISSN pri članku:1424-8220
DOI:10.3390/s20247328 Povezava se odpre v novem oknu
COBISS.SI-ID:49646595 Povezava se odpre v novem oknu
Datum objave v RUL:24.01.2022
Število ogledov:988
Število prenosov:118
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Sensors
Skrajšan naslov:Sensors
Založnik:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:20.12.2020

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:propagacija EHG valov, križna korelacija, prazni intervali, intervali s popadki, hitrost prevajanja, napovedovanje prezgodnjega poroda

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P3-0124
Naslov:Metabolni in prirojeni dejavniki reproduktivnega zdravja, porod III

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj