izpis_h1_title_alt

Optimisation of pelvic imaging radiography protocols in plain radiology : a scoping review
ID Matjašič, Alenka (Avtor), ID Mekiš, Nejc (Avtor)

URLURL - Izvorni URL, za dostop obiščite https://www.uimr.ba/journal/index.php/rt/article/view/16 Povezava se odpre v novem oknu
.pdfPDF - Predstavitvena datoteka, prenos (639,75 KB)
MD5: CC9EF80B36F8CCD061E6188A61B40D6E

Izvleček
Introduction: The purpose of this work is to explore which studies have been performed in the field of radiation dose reduction in pelvic x-ray imaging and to determine optimization techniques for dose reduction. Materials and methods: A scoping review was performed by using databases Science Direct, PubMed, EBSCO Host and Springer Link. The keywords used were "radiography", "dose reduction", "pelvis" and "pelvic". Exclusion criteria were the keywords "CT" and "MRI". Results: 15 scientific articles that analyse the current dose impacts in selected institutions or regions were reviewed as a starting point to optimise protocols, to establish diagnostic reference levels, or to suggest different measures for dose reduction. Studies suggest the use of digital image receptor, adaptation of exposure parameters; they also point out the use of air gap instead of radiographic grid and investigate the usefulness of the gonad protection. A difference was noticed in developing countries that focus more on the establishment of DRLs and following the guidelines provided by other countries rather than developing new dose optimisation techniques. Conclusion: A pelvic x-ray must be performed with a low radiation dose impact that still doesn't compromise the diagnostic value of the image, which can be achieved by following the ALARA principle and with certain adjustments, suggested by the considered studies, especially with exposure parameters. The establishment of national and local diagnostic reference levels is also required.

Jezik:Angleški jezik
Ključne besede:radiation dose reduction, pelvic imaging, optimization, diagnostic reference levels
Vrsta gradiva:Članek v reviji
Tipologija:1.02 - Pregledni znanstveni članek
Organizacija:ZF - Zdravstvena fakulteta
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Datum sprejetja članka:21.09.2021
Datum objave:01.11.2021
Leto izida:2021
Št. strani:Str. 3-11
Številčenje:Vol. 12, no. 1
PID:20.500.12556/RUL-133612 Povezava se odpre v novem oknu
UDK:616-073
ISSN pri članku:2637-3297
DOI:10.48026/issn.26373297.2021.12.1.3 Povezava se odpre v novem oknu
COBISS.SI-ID:87755267 Povezava se odpre v novem oknu
Datum objave v RUL:03.12.2021
Število ogledov:851
Število prenosov:143
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Radiološke tehnologije
Skrajšan naslov:Radiol. tehnol.
Založnik:Udruženje inžinjera medicinske radiologije u Federaciji Bosne i Hercegovine
ISSN:2637-3297
COBISS.SI-ID:28330246 Povezava se odpre v novem oknu

Sekundarni jezik

Jezik:Ni določen
Ključne besede:zmanjšanje doze sevanja, slikanje medenice, optimizacija, diagnostične referenčne ravni

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj