izpis_h1_title_alt

Turbine flowmeter response to transitional flow regimes
ID Džemić, Zijad (Avtor), ID Širok, Brane (Avtor), ID Bizjan, Benjamin (Avtor)

URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S0955598617301279?via%3Dihub Povezava se odpre v novem oknu
.pdfPDF - Predstavitvena datoteka, prenos (1,68 MB)
MD5: 2D6C3329A3562436C214AF623FAC6ED2

Izvleček
In this paper, acceleration and deceleration performance of turbine flowmeters was investigated in transitional flow regimes. Different flow meters and peak gas flow rates were used, with a step flow transition induced by rapid closing and reopening of the pipeline valve. Hotwire anemometry was employed as a reference method to assess the dynamic response of turbine flowmeters. Results of this study suggest a good dynamic response of turbine flowmeters in accelerating flows, with only a slight delay of the turbine rotation. However, in decelerating flows, the response of the flowmeter turbine was found to be slow, with characteristic time constants up to 35 s and large resulting over-registration of transferred gas volume. Our findings were quantified by multiple regression models for flowmeter response times and over-registered volumes, which were both find to drop with Reynolds number and increase with the flowmeter size. Understanding dynamic response is essential to evaluate dynamic errors and evaluate overall measurement uncertainty.

Jezik:Angleški jezik
Ključne besede:turbine flowmeter, dynamic response, Reynolds number
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Recenzirani rokopis
Datum sprejetja članka:20.11.2017
Leto izida:2018
Št. strani:Str. 18-22
Številčenje:Vol. 59
PID:20.500.12556/RUL-126751 Povezava se odpre v novem oknu
UDK:532.57(045)
ISSN pri članku:0955-5986
DOI:10.1016/j.flowmeasinst.2017.11.006 Povezava se odpre v novem oknu
COBISS.SI-ID:15857179 Povezava se odpre v novem oknu
Datum objave v RUL:05.05.2021
Število ogledov:666
Število prenosov:263
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Flow measurement and instrumentation
Skrajšan naslov:Flow meas. instrum.
Založnik:Elsevier
ISSN:0955-5986
COBISS.SI-ID:169755 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.
Začetek licenciranja:01.03.2018

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:turbinski merilnik pretoka, dinamični odziv, Reynoldsovo število

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj