Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Efficacy of breast shielding during head computed tomography examination
ID
Zalokar, Nika
(
Avtor
),
ID
Mekiš, Nejc
(
Avtor
)
PDF - Predstavitvena datoteka,
prenos
(436,43 KB)
MD5: 9503E592AC2B88C1E033C8C9D86EA95D
Galerija slik
Izvleček
Background. Female breasts are exposed to scattered radiation regardless of not being included in the primary field during head CT. This study aimed to investigate whether the use of lead shielding is beneficial in dose reduction to the breasts during head CT. Patients and methods. The study was performed in two different hospitals on two different CT units and included 120 patients. Half of the measurements (n = 60) was conducted without the use of lead shielding and the other half (n = 60) with the use of lead shielding of 0.5 mm equivalent thickness. Results. Significant skin dose reduction to the breasts during head CT in both hospitals with the use of lead shielding was discovered; 81% (338.2 ± 43.7 μGy to 64.3 ± 18.8 μGy) in Hospital A and 74% (from 253.1 ± 35.1 μGy to 65.3 ± 16.9 μGy) in Hospital B. Conclusions. Considering the assumed carcinogenic effect of low doses of radiation, high frequency of the head CT scans and the significant reduction of radiation doses to the highly radiosensitive breasts, the use of lead shielding is highly recommendable.
Jezik:
Angleški jezik
Ključne besede:
scatter radiation
,
head CT
,
lead shielding
,
breasts
,
dose reduction
Tipologija:
1.01 - Izvirni znanstveni članek
Organizacija:
ZF - Zdravstvena fakulteta
Status publikacije:
Objavljeno
Različica publikacije:
Objavljena publikacija
Leto izida:
2021
Št. strani:
Str. 116-120
Številčenje:
Vol. 55, no. 1
PID:
20.500.12556/RUL-124556
UDK:
616-074
ISSN pri članku:
1318-2099
DOI:
10.2478/raon-2020-0044
COBISS.SI-ID:
25473795
Datum objave v RUL:
02.02.2021
Število ogledov:
1126
Število prenosov:
260
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Kopiraj citat
Objavi na:
Gradivo je del revije
Naslov:
Radiology and oncology
Skrajšan naslov:
Radiol. oncol.
Založnik:
Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:
1318-2099
COBISS.SI-ID:
32649472
Licence
Licenca:
CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:
http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:
To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:
02.02.2021
Sekundarni jezik
Jezik:
Slovenski jezik
Ključne besede:
razpršeno sevanje
,
računalniška tomografija glave
,
svinčeni ščit
,
prsi
,
zmanjšanje odmerka
Podobna dela
Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:
Nazaj