Vaš brskalnik ne omogoča JavaScript!
JavaScript je nujen za pravilno delovanje teh spletnih strani. Omogočite JavaScript ali pa uporabite sodobnejši brskalnik.
Repozitorij Univerze v Ljubljani
Nacionalni portal odprte znanosti
Odprta znanost
DiKUL
slv
|
eng
Iskanje
Brskanje
Novo v RUL
Kaj je RUL
V številkah
Pomoč
Prijava
Podrobno
Ocena potresne odpornosti montažne armiranobetonske hale : diplomska naloga
ID
Breznikar, Janez
(
Avtor
),
ID
Dolšek, Matjaž
(
Mentor
)
Več o mentorju...
,
ID
Babič, Anže
(
Komentor
)
PDF - Predstavitvena datoteka,
prenos
(3,19 MB)
MD5: 7393EE028A2A6742D23B43A476B5741B
PID:
20.500.12556/rul/edea5dec-ee43-4298-9e46-ba22612b1ca2
PDF - Priloga,
prenos
(12,41 MB)
MD5: 52D0E85F51FA0D8197011113E7297942
PID:
20.500.12556/rul/693a0aa1-a059-4533-9a88-1dcd9085b25b
Galerija slik
Izvleček
V diplomski nalogi obravnavamo potresno odpornost armiranobetonske montažne hale. Potresno odpornost preverjamo z uporabo standarda Evrokod 8-3 (SIST EN 1998-3, 2005). Za potresno analizo smo uporabili obe metodi, ki temeljita na linearni elastični analizi, in sicer metodo s horizontalnimi silami in metodo s q-faktorjem. Pri določitvi kapacitet stikov konstrukcije smo si zaradi pomanjkljivosti Evrokoda 8-3 pomagali z drugimi viri (Zoubek, 2015). Za modeliranje konstrukcije in analizo smo uporabili računalniški program SAP2000, z računalniškim programom DIAS pa smo izračunali upogibno odpornost stebrov. Kontrole potresne odpornosti smo izvedli za mejno stanje velikih poškodb (SD) in mejno stanje omejitve poškodb (DL). Ugotovili smo, da so pri tovrstnih konstrukcijah problematični predvsem stiki med montažnimi elementi. To potrjujejo tudi kontrole prečne sile v stiku steber-prečka za mejno stanje SD, ki se za obravnavani metodi ne izidejo. Kontrole strižne sile v stebrih se za vse obravnavane stebre pri obeh metodah in mejnih stanjih izidejo. Kontrole glede na upogib se pri metodi s horizontalnimi silami ne glede na obravnavano mejno stanje izidejo, medtem ko se pri metodi s q-faktorjem pri mejnem stanju SD kontrola glede upogiba ne izide. Vrednosti pomikov konstrukcije pri metodi s q-faktorjem pri mejnem stanju DL niso presežene. Izkaže se, da obravnavana montažna hala ni sposobna prevzeti projektnega potresnega vpliva. Več informacij o potresni ranljivosti objekta bi lahko pridobili z analizo potresnega tveganja, vendar uporaba takšnega pristopa presega okvire te diplomske naloge.
Jezik:
Slovenski jezik
Ključne besede:
armiranobetonska montažna hala
,
ocena potresne odpornosti
,
metoda s horizontalnimi silami
,
metoda s q-faktorjem
,
Evrokod 8-3
Vrsta gradiva:
Diplomsko delo/naloga
Tipologija:
2.11 - Diplomsko delo
Organizacija:
FGG - Fakulteta za gradbeništvo in geodezijo
Založnik:
[J. Breznikar]
Leto izida:
2017
PID:
20.500.12556/RUL-96490
UDK:
624.042.7:624.012.45(043.2)
COBISS.SI-ID:
8193121
Datum objave v RUL:
02.10.2017
Število ogledov:
2697
Število prenosov:
1029
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
BREZNIKAR, Janez, 2017,
Ocena potresne odpornosti montažne armiranobetonske hale : diplomska naloga
[na spletu]. Diplomsko delo. J. Breznikar. [Dostopano 31 marec 2025]. Pridobljeno s: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=slv&id=96490
Kopiraj citat
Objavi na:
Sekundarni jezik
Jezik:
Angleški jezik
Naslov:
Seismic performance assessment of precast concrete building : Graduation thesis
Izvleček:
A seismic performance assessment of precast concrete building is presented in the thesis by using Eurocode 8-3 standard (SIST EN 1988-3, 2005). Methods based on linear elastic analysis, i.e. the lateral force method and the q-factor method, were used for the estimation of the seismic effects on the structural elements. Due to shortcomings of Eurocode 8-3, the resistance of beam-column joints were determined according to Zoubek (2015). The structure was modelled and analysed with the computer programme SAP2000, whereas the computer programme DIAS was used to calculate flexural resistance of columns. Presented are design checks for significant damage (SD) limit state and limit state of damage limitations (DL). The results showed that the beam-column joints are the critical structural component of the investigated building. These structural components were not approved by the SD limit state criteria taking into account the transverse force at the beam-column joints which was obtained either by the lateral force or the q-factor method. On the contrary, the shear strength of beams was found sufficient in the case of both methods of seismic analysis. However, the flexural strength of the columns was insufficient if the seismic action effect corresponding to SD limit state was obtained by using q-factor method. It was also found that the requirements for DL limit states are also fulfilled. It turned out that the investigated precast concrete building is not capable to resist to the design seismic action. However, more information on the seismic vulnerability of the building could be obtained by performing seismic risk assessment, but using such comprehensive approach is beyond the scope of this thesis.
Ključne besede:
precast concrete building
,
seismic performance assessment
,
lateral force method
,
q-factor approach
,
Eurocode 8-3
Podobna dela
Podobna dela v RUL:
The Slovenian Reception of Marceline Desbordes-Valmore's Love Poetry
Problemi pri prevajanju bosanskega pesnika Abdulaha Sidrana v slovenski jezik
The role of illustrations in the process of translating picturebooks from English to Slovene
"Če hočete rešiti svojo umazano črno dušo, se morate vpisati v partijo." Ideološki elementi v izbranih prevodih italijanskih književnih besedil v slovenščino
Public funds for translating literature into Slovene
Podobna dela v drugih slovenskih zbirkah:
Numerično modeliranje toplotnega prenosnika po metodi končnih elementov
Konstruiranje nadgradnje gasilskega vozila
Konstrukcija orodja za tlačno litje prokrova elektromotorja iz aluminija
Uvod v računalniške simulacije
Postopek konstruiranja orodja za tlačno litje aluminija
Nazaj