izpis_h1_title_alt

Ropot pri spravilu lesa z žičnim žerjavom Urus III
ID Lipoglavšek, Marjan (Author)

.pdfPDF - Presentation file, Download (640,81 KB)
MD5: 536CA4E94C2D72D85BBDB314DA00FBFA

Abstract
V članku so prikazani rezultati meritev ropota na dveh deloviščih pri spravilu lesa z 2 žičnima žerjavoma URUS III na kamionu TAM. Ropot med prostim tekom ne presega NR 70, med polno vožnjo pa presega NR 90. Obremenitve strojnika z ropotom (Lekv) so znašale v vsem delovnem času med 82 in 90 dB(A), najmanj pri tesno zaprti, največ pri slabo zaprti kabini. Večinoma presegajo dopustne meje 85 dB(A), vendar če jih primerjamo z mejami za ropot s prekinitvami, so bili strojniki izpostavljeni sluhu škodljivemu ropotu samo pri slabo zaprti kabini, pri odprti pa ne.

Language:Slovenian
Keywords:ropot, spravilo lesa, žični žerjav, obremenitev strojnikov z ropotom
Typology:1.01 - Original Scientific Article
Organization:BF - Biotechnical Faculty
Year:1993
Number of pages:Str.139-154
Numbering:Št. 41
PID:20.500.12556/RUL-69751 This link opens in a new window
UDC:630*3
ISSN on article:0351-3114
COBISS.SI-ID:41022976 This link opens in a new window
Publication date in RUL:10.07.2015
Views:1415
Downloads:200
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Zbornik gozdarstva in lesarstva. forest and wood science & technology
Shortened title:Zb. gozd. lesar.
Publisher:Gozdarski inštitut Slovenije, Biotehniška fakulteta, Oddelek za gozdarstvo in obnovljive gozdne vire, Biotehniška fakulteta, Oddelek za lesarstvo
ISSN:0351-3114
COBISS.SI-ID:6206978 This link opens in a new window

Secondary language

Language:English
Abstract:
The article presents the results of noise measurements in two working places carried out during two days at wood skidding by means of two URUS III cable crane on a TAM trnek. The noise during idle motion did not exceed NR 70 but during load drive it exceeded NR 90. The noise loads of an operator (Lekv) were between 82 and 90 dB(A) during the entire working time, the lowest with a cabin tightly closed and the highest with a cabin insufficiently closed. They mostly exceeded the still permitted limits of 85 dB(A) yet if compared with the limits permitted far the noise with interruptions, operators were exposed to noise harmful to hearing only with an insufficiently closed cabin and not with an open one.