Your browser does not allow JavaScript!
JavaScript is necessary for the proper functioning of this website. Please enable JavaScript or use a modern browser.
Repository of the University of Ljubljana
Open Science Slovenia
Open Science
DiKUL
slv
|
eng
Search
Advanced
New in RUL
About RUL
In numbers
Help
Sign in
Details
Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation
ID
Sorrentino, Riccardo
, Institut Jožef Stefan. Odsek za avtomatiko, biokibernetiko in robotiko (E1) (
Author
),
ID
Ávila Mireles, Edwin Johnatan
, Institut Jožef Stefan. Odsek za avtomatiko, biokibernetiko in robotiko (E1) (
Author
),
ID
Babič, Jan
, Institut Jožef Stefan. Odsek za avtomatiko, biokibernetiko in robotiko (E1) (
Author
),
ID
Supej, Matej
, Univerza v Ljubljani, Fakulteta za šport (
Author
),
ID
Mekjavić, Igor B.
, Institut Jožef Stefan. Odsek za avtomatiko, biokibernetiko in robotiko (E1) (
Author
),
ID
McDonnell, Adam
, Institut Jožef Stefan. Odsek za avtomatiko, biokibernetiko in robotiko (E1) (
Author
)
PDF - Presentation file,
Download
(1,76 MB)
MD5: 2355A6DD54D9DB5F28C99B5FA5C8A895
URL - Source URL, Visit
https://physoc.onlinelibrary.wiley.com/doi/10.14814/phy2.16034
Image galllery
Abstract
This study compared the joint kinematics between the front squat (FS) conducted in the upright (natural gravity) position and in the supine position on a short arm human centrifuge (SAHC). Male participants (N = 12) with no prior experience exercising on a centrifuge completed a FS in the upright position before (PRE) and after (POST) a FS exercise conducted on the SAHC while exposed to artificial gravity (AG). Participants completed, in randomized order, three sets of six repetitions with a load equal to body weight or 1.25 × body weight for upright squats, and 1 g and 1.25 g at the center of gravity (COG) for AG. During the terrestrial squats, the load was applied with a barbell. Knee (left/right) and hip (left/right) flexion angles were recorded with a set of inertial measurement units. AG decreased the maximum flexion angle (MAX) of knees and hips as well as the range of motion (ROM), both at 1 and 1.25 g. Minor adaptation was observed between the first and the last repetition performed in AG. AG affects the ability to FS in naïve participants by reducing MAX, MIN and ROM of the knees and hip.
Language:
English
Keywords:
artificial gravity
,
human centrifugation
,
motion analysis
,
movement adaptation
,
squat kinematic
Work type:
Article
Typology:
1.01 - Original Scientific Article
Organization:
FŠ - Faculty of Sport
Publication status:
Published
Publication version:
Version of Record
Year:
2024
Number of pages:
13 str.
Numbering:
Vol. 12, iss. 13, art. 16034
PID:
20.500.12556/RUL-190385
UDC:
681.5
ISSN on article:
2051-817X
DOI:
10.14814/phy2.16034
COBISS.SI-ID:
200899331
Publication date in RUL:
27.10.2026
Views:
78
Downloads:
28
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Copy citation
Share:
Record is a part of a journal
Title:
Physiological reports
Shortened title:
Physiol. reports
Publisher:
Wiley
ISSN:
2051-817X
COBISS.SI-ID:
5605658
Licences
License:
CC BY 4.0, Creative Commons Attribution 4.0 International
Link:
http://creativecommons.org/licenses/by/4.0/
Description:
This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Secondary language
Language:
Slovenian
Keywords:
umetna gravitacija
,
centrifuga
,
analiza gibanja
,
prilagoditev gibanja
,
kinematika sklepov
Projects
Funder:
ARIS - Slovenian Research and Innovation Agency
Project number:
P2-0076
Name:
Avtomatika, Robotika in Biokibernetika
Similar documents
Similar works from RUL:
Similar works from other Slovenian collections:
Back