Prispevek obravnava študijo primera dvostanovanjske stavbe z nosilnim sistemom iz križno lepljenega lesa (CLT), pri kateri so bili analizirani raven zvočne zaščite in oblikovani predlogi za njeno izboljšanje. Cilji raziskave so obsegali eksperimentalno določitev zvočne izolirnosti zunanjih in notranjih ločilnih elementov ter ovrednotenje rezultatov glede na veljavne zahteve in priporočila, s poudarkom na obnašanju konstrukcij v nizkofrekvenčnem območju. Meritve so bile izvedene skladno s standardi ISO 16283-1, -2 in -3. Izmerjena zvočna izolirnost predelne stene med stanovanjema (R′w = 71 dB) presega minimalne zahteve in potrjuje učinkovito zasnovo ter izvedbo konstrukcijskih detajlov brez izrazitih akustičnih mostov. Zvočna izolirnost fasade z oknom (R′w = 32 dB) izpolnjuje predpisane mejne vrednosti, pri čemer spektralna analiza razkrije manj ugoden odziv v nizkofrekvenčnem območju, vzroka pa na podlagi izvedenih meritev ni mogoče enoznačno določiti. Medetažna konstrukcija z L′n,w = 44 dB ustreza zahtevam za stanovanjske stavbe, vendar nizkofrekvenčni prenos ostaja značilen izziv CLT-sistemov. Iz navedenega izhaja, da visoka vrednost R′w in nizka vrednost L′n,w še ne zagotavljata optimalne zvočne zaščite v vseh primerih. Rezultati potrjujejo, da je z ustreznim projektiranjem, zgodnjo vključitvijo akustičnega strokovnjaka in kakovostno izvedbo mogoče doseči visoko raven akustične učinkovitosti lesenih stavb, ugotovitve pa so uporabne tudi pri načrtovanju objektov s podobnimi konstrukcijskimi sistemi. Hkrati rezultati spektralne analize fasade kažejo, da zmanjšana zvočna izolirnost v nizkofrekvenčnem območju lahko predstavlja omejitev pri zaščiti pred zunanjimi viri z izrazitim nizkofrekvenčnim spektrom, kot so toplotne črpalke, kar je pomembno upoštevati pri nadaljnjem akustičnem načrtovanju.

Language:Slovenian
Keywords:dvostanovanjska stavba, križno lepljen les, zvočna izolirnost, udarni zvok, zvok po zraku
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FGG - Faculty of Civil and Geodetic Engineering
Publication status:Published
Publication version:Version of Record
Year:2026
Number of pages:Str. 199-209
Numbering:Letn. 75, št. 3
PID:20.500.12556/RUL-189777 This link opens in a new window
UDC:694.1:691:699.844
ISSN on article:0017-2774
COBISS.SI-ID:300998403 This link opens in a new window
Publication date in RUL:15.10.2026
Views:156
Downloads:66
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Gradbeni vestnik : glasilo Zveze društev gradbenih inženirjev in tehnikov Slovenije
Shortened title:Gradb. vestn.
Publisher:Zveza društev gradbenih inženirjev in tehnikov Slovenije
ISSN:0017-2774
COBISS.SI-ID:859140 This link opens in a new window

Licences

License:CC BY-SA 4.0, Creative Commons Attribution-ShareAlike 4.0 International
Link:http://creativecommons.org/licenses/by-sa/4.0/
Description:This Creative Commons license is very similar to the regular Attribution license, but requires the release of all derivative works under this same license.

Secondary language

Language:English
Title:Sound insulation challenges in modern timber construction
Abstract:
This article presents a case study of a semi-detached residential building with a load-bearing system made of cross-laminated timber (CLT), in which sound insulation performance was assessed and improvement measures were proposed. The research objectives included the experimental determination of airborne and impact sound insulation of façade and internal elements, evaluation of the results against regulations and recommendations, and consideration of structural behaviour at low frequencies. Sound insulation measurements were conducted in accordance with ISO 16283-1, -2 and -3. The partition wall between the two dwellings achieved a high airborne sound insulation performance (R′w = 71 dB), exceeding minimum requirements and confirming effective structural design and execution. The façade achieved an R′w of 32 dB, satisfying the limit values; however, spectral analysis revealed a less favourable response in the low-frequency range, the cause of which could not be conclusively determined based on the measurements performed. The inter-storey floor exhibited an impact sound level of L′n,w 44 dB, complying with residential building requirements, while low-frequency impact transmission remains a challenge for the CLT systems. It follows from the above that a high R′w value and a low L′n,w value do not necessarily guarantee optimal acoustic protection in all cases. The results show that high acoustic performance in timber buildings can be achieved through appropriate design, early involvement of an acoustic specialist, and high-quality construction. In addition, the findings indicate that the reduced low-frequency sound insulation performance of the façade may result in increased sensitivity to external low-frequency noise sources, such as heat pumps, which should be carefully considered in future acoustic design and system placement.