Background: Atrial fibrillation/flutter (AF/AFl) is commonly diagnosed arrhythmia, associated with increased morbidity and mortality. Therefore, we have to improve our early AF/AFl diagnostics. Several studies indicated association between conduction delay, excessive atrial ectopic beats (AEBs) and AF/AFl onset. Association with some other AEB features is less clear. Objective: To validate the role of early AEBs from Holter-ECG in relation to documented AF/AFl events. Methods and Results: We enrolled 14 consecutive patients (6 female, median 60.5 years) with documented AF/AFl during or within 6 months after Holter-ECG (AF-group). Control group consisted of 10 clinically similar consecutive patients (5 female, median 64.5 years), without any evidence of AF/AFl, but with comparable burden of AEBs. Holter-ECGs were examined with 3-channel Holter system (Schiller, Darwin2 software). 24-hour data were analyzed for number and/or burden (%) of: a) AF/AFl, b) AEBs, c) early-AEBs (coupling interval cut-off <530 ms), d) AEB pairs, triplets, runs, and e) bigeminy. In addition, P-wave duration (cut-off <130 ms), PQ, QRS, and QTc were measured. AF-group had higher burden of early-AEBs (p<0.03) and longer P-waves (p<0.05) than controls. In both groups, non-conducted and aberrantly-conducted early-AEBs, AEBs in bigeminy, pairs, triplets and runs were found, as-well-as no difference for PQ, QRS, and QTc (p=NS). The majority of 243 AF/AFl events started during day-time and in 83% with early-AEBs. Before AF onset, outbursts of early-AEBs were encountered in 58% of patients.

Language:English
Keywords:atrijska fibrilacija, motnje srčnega ritma, preddvorni ektopični utripi, elektrokardiogram, holtersko monitoriranje
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:MF - Faculty of Medicine
Publication status:Published
Publication version:Version of Record
Year:2025
Number of pages:Str. 3–15
Numbering:Letn. 94, št. 1/2
PID:20.500.12556/RUL-184186 This link opens in a new window
UDC:616.12-008.313
ISSN on article:1318-0347
DOI:10.6016/ZdravVestn.3532 This link opens in a new window
COBISS.SI-ID:227806723 This link opens in a new window
Publication date in RUL:01.07.2026
Views:292
Downloads:113
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Zdravniški vestnik : glasilo Slovenskega zdravniškega društva
Publisher:Slovensko zdravniško društvo
ISSN:1318-0347
COBISS.SI-ID:32893696 This link opens in a new window

Licences

License:CC BY-NC 4.0, Creative Commons Attribution-NonCommercial 4.0 International
Link:http://creativecommons.org/licenses/by-nc/4.0/
Description:A creative commons license that bans commercial use, but the users don’t have to license their derivative works on the same terms.

Secondary language

Language:Slovenian
Title:Zgodnji preddvorni ektopični utripi in upočasnjen preddvorni prevod napovedujejo preddvorno fibrilacijo
Abstract:
Izhodišča: Preddvorna fibrilacija/undulacija (AF/AU) je pogosta motnja srčnega ritma, ki je povezana z višjo umrljivostjo in obolevnostjo. Zato jo je treba čim prej diagnosticirati. Rezultati več raziskav kažejo na povezavo med upočasnjenim preddvornim prevodom, velikim številom preddvornih ektopičnih utripov (AES) in pojavom AF/AU. Manj jasna je povezava z nekaterimi drugimi značilnostmi AES. Cilj raziskave: Vrednotiti smo želeli pomen zgodnjih AES pri holterskem elektrokardiogramu (EKG) v povezavi z zabeleže-nimi epizodami AF/AU. Metode in rezultati: V pilotsko raziskavo smo vključili 14 zaporednih bolnikov (6 žensk, mediana starost 60,5 leta) z doku-mentirano AF/AU v zapisu holterskega EKG ali do 6 mesecev po njem (skupina z AF/AU). V kontrolni skupini je bilo 10 zapo-rednih bolnikov s podobno klinično sliko (5 žensk, mediana starost 64,5 leat) brez AF/AU v anamnezi, vendar s podobnim bremenom AES. Holterski EKG smo beležili s 3-kanalnim sistemom (Schiller, Darwin2 software). V 24-urnih zapisih EKG smo analizirali število in/ali breme (%) naslednjih parametrov: a) AF/AU, b) AES, c) zgodnjih AES (vezni interval < 530 ms), d) AES v parih, tripletih in salvah in e) prisotnost bigeminije; poleg tega pa še trajanje vala P (normalna vrednost < 130 ms), PQ, QRS in QTc. Skupina z AF/AU je imela večje breme zgodnjih AES (p< 0,03) in daljši val P (p< 0,05) kot kontrolna skupina. V obeh skupinah smo zabeležili neprevedene in aberantno prevedene AES, AES v bigeminiji, parih, tripletih in salvah. Prav tako ni bilo razlike v trajanju PQ, QRS in QTc (p=NS). Večina od 243 primerov AF/AU se je sprožila v dnevnem času, v 83 % z zgodnjo AES. Pri 58 % smo zabeležili pred pojavom AF/AU porast števila zgodnjih AES.Zaključek: Večje breme zgodnjih AES v holterskem EKG in daljše trajanje vala P napovedujejo pojav AF/AU.

Keywords:atrial fibrillation, atrial ectopic beats, electrocardiogram, holter-monitoring