izpis_h1_title_alt

Measurement corrections for temperature effects in Coriolis mass flow meters for cryogenic, liquid hydrogen (▫$LH_2$▫) applications
ID Kutin, Jože (Avtor), ID Bobovnik, Gregor (Avtor), ID Mole, Nikolaj (Avtor), ID Schakel, Menne D. (Avtor), ID Büker, Oliver (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (833,02 KB)
MD5: 6068B999A988097A1F8F4714485E7024
URLURL - Izvorni URL, za dostop obiščite https://www.sciencedirect.com/science/article/pii/S0263224124010406 Povezava se odpre v novem oknu

Izvleček
To link traceable flow calibrations of Coriolis meters at ambient conditions to flow measurements in cryogenic, liquid hydrogen (▫$LH_2$▫) applications, physical effects of very low temperatures on the calibration factor must be satisfactorily predicted by temperature correction methods. In this paper, four correction models are investigated, which differ in the sense of which temperature effects they cover and how these effects are determined. These correction models were applied to three Coriolis meter designs – straight, arc and U-tube. As a reference value in the evaluation, we use the simulation results with the finite element model that incorporates temperature effects related to elastic material properties, thermal strains and thermal stresses. The best agreement (within ± 0.2 % for the curved tubes) is achieved by the correction model that considers the known temperature dependence of the tube elastic properties as well as the dimensional changes due to thermal strain.

Jezik:Angleški jezik
Ključne besede:Coriolis mass flow meterscryogenic liquids, temperature effects, correction model, finite element model
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:13 str.
Številčenje:Vol. 237, art. 115155
PID:20.500.12556/RUL-159304 Povezava se odpre v novem oknu
UDK:681.121.5:532.57:519.62
ISSN pri članku:0263-2241
DOI:10.1016/j.measurement.2024.115155 Povezava se odpre v novem oknu
COBISS.SI-ID:200846339 Povezava se odpre v novem oknu
Datum objave v RUL:05.07.2024
Število ogledov:7
Število prenosov:0
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Measurement : journal of the International Measurement Confederation
Skrajšan naslov:Measurement
Založnik:Institute of Measurement and Control
ISSN:0263-2241
COBISS.SI-ID:25917696 Povezava se odpre v novem oknu

Licence

Licenca:CC BY-NC-ND 4.0, Creative Commons Priznanje avtorstva-Nekomercialno-Brez predelav 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by-nc-nd/4.0/deed.sl
Opis:Najbolj omejujoča licenca Creative Commons. Uporabniki lahko prenesejo in delijo delo v nekomercialne namene in ga ne smejo uporabiti za nobene druge namene.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:Coriolisovi merilniki pretoka, kriogene kapljevine, temperaturni vplivi, korekcijski model, metoda končnih elementov

Projekti

Financer:Drugi - Drug financer ali več financerjev
Program financ.:Joint Research Project (JRP) “Metrology infrastructure for high-pressure gas and liquified hydrogen flows”
Številka projekta:20IND11
Akronim:MetHyInfra

Financer:EC - European Commission
Program financ.:EMPIR programme

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P2-0223
Naslov:Prenos toplote in snovi

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj