This paper aims to determine the need for additional imaging verification when using the auto beam hold function in radiotherapy of prostate cancer patients with inserted gold fiducial markers. Forty patients who underwent irradiation of the prostate and twenty with prostate and pelvic lymph node radiotherapy were included in the retrospective study. Intrafraction shifts during irradiation were compared with the auto beam hold function in the translational directions. The function was used with time tracking (5 seconds), a tolerance limit for marker deviations (4 mm), and bone structures in the large irradiation field (5 mm). The need for additional image verification was higher in the larger irradiation field group. When translational shifts were analysed, a statistically significant difference in the vertical direction was found in the group with only prostate irradiation (p = 0.013). A statistically significant difference in the lateral direction was found in the group with a larger irradiation field (p = 0.021). Translational shifts were not statistically significantly different between the two groups (p > 0.05). Conclusion: Intrafraction shifts of the prostate increase the need for additional imaging verification. The use of the auto beam hold function is effective in reducing errors.

Language:English
Keywords:prostate cancer, radiotherapy, intrafraction movement, 2-D kV imaging in radiotherapy, auto beam hold function
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:ZF - Faculty of Health Sciences
Publication status:Published
Publication version:Version of Record
Year:2023
Number of pages:Str. 301-306
Numbering:Vol. 38, no. 4
PID:20.500.12556/RUL-156054 This link opens in a new window
UDC:616-073:616-006
ISSN on article:1451-3994
DOI:10.2298/NTRP2304301S This link opens in a new window
COBISS.SI-ID:194385667 This link opens in a new window
Publication date in RUL:06.05.2024
Views:420
Downloads:53
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Nuclear Technology & Radiation Protection
Shortened title:Nucl. Technol. Radiat. Prot.
Publisher:Vinča Instituta of Nuclear Sciences
ISSN:1451-3994
COBISS.SI-ID:18296103 This link opens in a new window

Licences

License:CC BY-NC-ND 3.0, Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported
Link:http://creativecommons.org/licenses/by-nc-nd/3.0/
Description:You are free to reproduce and redistribute the material in any medium or format. You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes. If you remix, transform, or build upon the material, you may not distribute the modified material. You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back