izpis_h1_title_alt

Microfluidic electrochemical glucose biosensor with in situ enzyme immobilization
ID Lokar, Nina (Author), ID Pečar, Borut (Author), ID Možek, Matej (Author), ID Vrtačnik, Danilo (Author)

.pdfPDF - Presentation file, Download (3,71 MB)
MD5: 2254ABD57021F42A64004E12893430F4
URLURL - Source URL, Visit https://www.mdpi.com/2079-6374/13/3/364 This link opens in a new window

Abstract
The development and characterization of a microfluidic electrochemical glucose biosensor are presented herein. The transducer part is based on thin-film metal electrodes on a glass substrate. The biological recognition element of the biosensor is the pyrroloquinoline quinone–glucose dehydrogenase (PQQ-GdhB) enzyme, selectively in situ immobilized via microcontact printing of a mixed self-assembling monolayer (SAM) on a gold working electrode, while the microfluidic part of the device comprises microchannel and microfluidic connections formed in a polydimethylsiloxane (PDMS) elastomer. The electrode properties throughout all steps of biosensor construction and the biosensor response to glucose concentration and analyte flow rate were characterized by cyclic voltammetry and chronoamperometry. A measurement range of up to 10 mM in glucose concentration with a linear range up to 200 µM was determined. A detection limit of 30 µM in glucose concentration was obtained. Respective biosensor sensitivities of 0.79 nA/µM/mm$^2$ and 0.61 nA/µM/mm$^2$ were estimated with and without a flow at 20 µL/min. The developed approach of in situ enzyme immobilization can find a wide number of applications in the development of microfluidic biosensors, offering a path towards continuous and time-independent detection.

Language:English
Keywords:microfluidic glucose biosensor, electrochemical biosensor, thin film electrode, enzyme in situ immobilization, chronoamperometry, cyclic voltammetry
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FE - Faculty of Electrical Engineering
Publication status:Published
Publication version:Version of Record
Year:2023
Number of pages:16 str.
Numbering:Vol. 13, iss. 3, art. 364
PID:20.500.12556/RUL-154088 This link opens in a new window
UDC:602.1:53.082.9
ISSN on article:2079-6374
DOI:10.3390/bios13030364 This link opens in a new window
COBISS.SI-ID:145284355 This link opens in a new window
Publication date in RUL:24.01.2024
Views:312
Downloads:25
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Biosensors
Shortened title:Biosensors
Publisher:MDPI
ISSN:2079-6374
COBISS.SI-ID:523007769 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:mikrofluidni biosenzor glukoze, elektrokemični biosenzor, tankoplastna elektroda, imobilizacija encima in situ, kronoamperometrija, ciklična voltametrija

Projects

Funder:ARRS - Slovenian Research Agency
Project number:P2-0244
Name:Mikrostrukture in nanostrukture

Funder:ARRS - Slovenian Research Agency
Project number:1000-22-0510

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back