izpis_h1_title_alt

Vloga 3D SPECT/CT slikovnega sistema : diplomsko delo
ID Mišič, Polona (Author), ID Olivo, Sara (Author), ID Rep, Sebastijan (Mentor) More about this mentor... This link opens in a new window, ID Ležaič, Luka (Comentor), ID Žibert, Janez (Reviewer)

.pdfPDF - Presentation file, Download (961,64 KB)
MD5: 0728AEDFC9387721E54CC246587AF29B

Abstract
Uvod: Hibridni sistem SPECT/CT predstavlja diagnostično orodje v nuklearno-medicinskem slikanju, ki zagotavlja tako funkcionalne kot anatomske informacije in s tem omogoča natančno korekcijo slike SPECT zaradi slabljenja. Napredek na področju digitalnih tehnologij zdaj hitro izpodriva starejše analogne tehnike in tako se sedaj uporabljajo detektorji iz kadmijevega cinkovega telurida (CZT). V zadnjem času se poleg revolucije na področju detektorjev pojavlja tudi preskok v smeri modificiranih modelov naprav in sicer 360° 3D SPECT/CT. Namen: Namen diplomskega dela je s sistematičnim pregledom literature predstaviti novo generacijo 3D SPECT/CT sistema, in sicer njegovo zgradbo, delovanje in primerjavo z že obstoječimi SPECT/CT aparati. Metode dela: Pri pisanju diplomske naloge smo uporabili deskriptivno metodo dela in sicer sistematični pregled literature. Izhajali smo iz strokovnih člankov in raziskav tako v slovenščini in angleščini kot tudi v francoščini in poljščini, ki smo jih pridobili na spletnih straneh različnih podatkovnih baz. Sistematični pregled literature je trajal od novembra 2022 do aprila 2023. Rezultati: Vsem raziskavam je bilo skupno, da imata novejša sistema 360° 3D SPECT/CT povečano senzitivnost, števnost, prostorsko ločljivost in pa krajši čas zajema, ki kljub temu zagotavlja optimalno kakovost slike. Glede natančnosti v napovedanosti diagnoz pa se s predhodnimi sistemi ne razlikujeta. Razprava in zaključek: Na podlagi raziskav smo ugotovili, da nova aparata 3D SPECT/CT Veriton in StarGuide predstavljata pomemben napredek v diagnostiki in terapiji različnih bolezni. Njuna negativna lastnost pa so visoki stroški nakupa in vzdrževanja. Zaradi prednosti v primerjavi s konvencionalnimi SPECT/CT aparati, lahko pomagajo pri bolj natančni in zgodnejši diagnozi ter izboljšajo kakovost zdravljenja.

Language:Slovenian
Keywords:diplomska dela, radiološka tehnologija, SPECT/CT, 360° 3D SPECT/CT, Veriton, StarGuide, detektorji CZT
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:ZF - Faculty of Health Sciences
Place of publishing:Ljubljana
Publisher:[P. Mišič : S. Olivo]
Year:2023
Number of pages:27 str.
PID:20.500.12556/RUL-150001 This link opens in a new window
UDC:616-07
COBISS.SI-ID:164331523 This link opens in a new window
Publication date in RUL:13.09.2023
Views:1644
Downloads:214
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:The role of 3D SPECT/CT imaging system : diploma work
Abstract:
Introduction: SPECT/CT hybrid system is a new diagnostic tool in nuclear medicine imaging, providing both functional and anatomical images, allowing accurate attenuation correction of SPECT images. Advances in digital technologies are now rapidly replacing older analogue techniques and cadmium zinc telluride (CZT) detectors are now being used. Recently, in addition to the revolution in detectors, there has also been a leap towards modified device designs 360° 3D SPECT/CT. Purpose: The aim of this diploma work is to present a new generation of 3D SPECT/CT systems, mostly it's structure, operation and comparison with existing SPECT/CT devices, by means of a systematic review of the literature. Methods: In this diploma work, we used a descriptive searching method, namely a systematic literature review. We selected different articles and researches in Slovenian language and English, as well as in French and Polish, which we have obtained from various databases on the internet. The systematic literature review was happening from November 2022 to April 2023. Results: All of the chosen studies, have shown that the new 360° 3D SPECT/CT systems have increased sensitivity of tomographic counts, spatial resolution and shorter acquisition times, while still keeping optimal image quality. However, in terms of accuracy in predicting diagnoses, they do not differ from the previous systems. Discussion and conclusion: Based on our research, we have concluded that the new Veriton and StarGuide systems represent a significant advance in the diagnosis and treatment of various diseases detectable by SPECT/CT imaging. Their only negative side is the high cost of purchase and maintenance. Due to their advantages compared to conventional SPECT/CT systems, they can help to make a more accurate diagnosis and improve the quality of treatment.

Keywords:diploma theses, radiologic technology, SPECT/CT, 360° 3D SPECT/CT, Veriton, StarGuide, CZT detekctors

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back