izpis_h1_title_alt

Optimization of brain tumours irradiation : determining the set-up margin
ID Žager Marciuš, Valerija (Author), ID Dolenc, Laura (Author), ID Smrdel, Uroš (Author)

.pdfPDF - Presentation file, Download (258,43 KB)
MD5: 888036DB5160C0B8399612B723416F70
URLURL - Source URL, Visit https://ntrp.vinca.rs/2022_3/Marcius2022_3.html This link opens in a new window

Abstract
The aim of this work was to evaluate whether the excising margin of the clinical tumor volume and planning target volume correspond with calculated radiation margin based on systematic errors, and definition of radiation margins of individual brain lobes. This research was a retrospective cross-sectional study. We checked the systematic errors and calculated their average and the size of radiation margins. The average systematic errors were calculated in four directions: lateral, longitudinal, vertical, and rotation. The largest average systematic error was calculated in the lateral direction in the cerebellar area, and the error was also statistically significant (p < 0.05). In rotational direction we notice the statistically significant difference in frontal lobe (p = 0.037), and cerebellar area (p = 0.002). The largest safety margin, as measured by the average systematic errors, is required for irradiation of the cerebellum. The safety margin size of 6.94 mm was calculated according to the formula of Van Herk. However, the smallest safety margin can be used for irradiation of the occipital lobe of the brain, namely 4.85 mm. The linear regression results that only cerebellar lesions affect lateral displacements. Based on our calculation of the mean systematic errors, we estimate that the clinical target volume – planning target volume safety margin can't be reduced further from the current 5 mm to a size of 3 mm without the use of image guided radiotherapy.

Language:English
Keywords:brain tumor, geometric verification of radiation, modern radiation therapy technique, radiation treatment margin, radiotherapy
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:ZF - Faculty of Health Sciences
Publication status:Published
Publication version:Version of Record
Publication date:01.01.2022
Year:2022
Number of pages:Str. 235-240
Numbering:Vol. 37, no. 3
PID:20.500.12556/RUL-144280 This link opens in a new window
UDC:616-073:615.849
ISSN on article:1451-3994
DOI:10.2298/NTRP2203235Z This link opens in a new window
COBISS.SI-ID:141099523 This link opens in a new window
Publication date in RUL:09.02.2023
Views:376
Downloads:66
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Nuclear Technology & Radiation Protection
Shortened title:Nucl. Technol. Radiat. Prot.
Publisher:Vinča Instituta of Nuclear Sciences
ISSN:1451-3994
COBISS.SI-ID:18296103 This link opens in a new window

Licences

License:CC BY-NC-ND 3.0, Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported
Link:http://creativecommons.org/licenses/by-nc-nd/3.0/
Description:You are free to reproduce and redistribute the material in any medium or format. You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes. If you remix, transform, or build upon the material, you may not distribute the modified material. You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Licensing start date:06.02.2023

Secondary language

Language:Undetermined
Keywords:možganski tumor, geometrijska verifikacija obsevanja, sodobna tehnika obsevanja, rob obsevanja, radioterapija

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back