DOLOČANJE KOMPENZACIJSKE FUNKCIJE AKTIVNEGA FILTRA NA OSNOVI PRISPEVKA PORABNIKA K HARMONSKEMU POPAČENJU
ID ŠPELKO, ALJAŽ (Avtor), ID Papič, Igor (Mentor) Več o mentorju... Povezava se odpre v novem oknu

.pdfPDF - Predstavitvena datoteka, prenos (6,81 MB)
MD5: ED9FC590C7F0CB0FAE84DD3DC6ECFA76

Izvleček
V današnjih elektroenergetskih omrežjih je kakovost električne energije pomembna, saj se lahko zgodi, da podjetja ne morejo zagotavljati ustreznih izdelkov ob poslabšanju kakovosti električne energije. Kakovost električne energije delimo na več parametrov in eden izmed njih je tokovno in napetostno harmonsko popačenje. Vsakodnevno se v elektroenergetsko omrežje vgrajujejo nove naprave, ki povzročajo harmonsko popačenje, bodisi so vir harmonskega popačenja ali pa povzročajo resonanco s pasivnimi napravami oz. kompenzacijo. Takšne naprave največkrat srečamo pri industrijskih porabnikih, ki imajo večjo priključno moč in vgrajeno kompenzacijo jalove moči. Nekatere imajo že vgrajen aktivni filter, ki kompenzira harmonsko popačenje. V tem primeru se lahko le posodobi njegov algoritem z novo predlagano kompenzacijsko funkcijo aktivnega filtra, ki temelji na določanju reference aktivnega filtra na podlagi prispevka porabnika. Predlagana kompenzacijska funkcija je tudi glavni doprinos k znanosti te doktorske disertacije. V prvem delu doktorske disertacije smo se osredotočili na pregled teoretičnega ozadja. Pregled zajema splošen opis harmonskega popačenja, vektorsko predstavitev trifaznih veličin, vire harmonskega počenja, določanje harmonske impedance. Prav tako je opisano, kako se lahko z različnimi pristopi zmanjšuje harmonsko popačenje. V elektroenergetskem sistemu so večinoma prisotne lihe harmonske komponente, sode harmonske komponente pa so prisotne le ob prehodnih pojavih. Lihe harmonske komponente delimo v tri značilne skupine. Značilne skupine so definirane z rotacijo posamezne harmonske komponente, ki jih delimo na nične, negativne in pozitivne harmonske komponente. Za določanje harmonskih komponent se največkrat uporablja hitro Fourierevo transformacijo, vendar se za regulacijske algoritme uporabljajo drugi pristopi, kot je npr. dq-transformacija, ki v realnem času ponazarja časovne veličine v vektorskem prostoru pri določeni frekvenci. Frekvenco določi harmonska komponenta, saj je treba vektorski prostor sinhronizirati na analizirano harmonsko komponento. Enosmerna vrednost te transformacije nam ponazarja vrednosti sinhronizirane harmonske komponente. Za določitev enosmerne vrednosti se uporabljajo nizkoprepustni filtri. Pri določanju prispevka porabnika k skupnemu popačenju so pomembni tudi viri harmonskega popačenja. Viri harmonskega popačenja se delijo na dve večji skupini, in sicer na potrošniška in industrijska bremena. Potrošniška bremena so večinoma manjših moči in običajno porabnik nima vgrajene kompenzacije jalove moči. V industrijska bremena spadajo večji trifazni močnostni pretvorniki, obločne peči in asinhronski motorji. Največkrat se porabnik odloči za kompenzacijo jalove moči, če ima vgrajene naprave z večjo močjo. V takšnih primerih je treba določiti lokacijo vira harmonskega popačenja, zaradi problema resonančnega ojačenja. Harmonsko popačenje se lahko tudi ojači s pasivno kompenzacijo jalove moči, če le ta ni ustrezno dimenzionirana oz. razglašena. Za ustrezno določitev prispevka porabnika je treba določiti harmonske impedance, posebej za omrežno in porabniško stran. Določanje harmonskih impedanc bo v doktorski disertaciji temeljilo na referenčnih impedancah, saj je prave oz. realne harmonske impedance praktično nemogoče določiti v realnem elektroenergetskem omrežju. Večinoma je treba harmonsko popačenje zmanjševati bodisi zaradi preseganja vrednosti, definiranih s standardi, oziroma zaradi zagotavljanja bolj kakovostnih izdelkov. Zmanjševanje harmonskega popačenja je lahko izvedeno na več načinov, s spremembo regulacijskih algoritmov pogonov, pasivnih kompenzatorjev ali z aktivnimi filtri. Za zmanjševanje harmonskega popačenja se uporablja uglašene pasivne filtre na določeno harmonsko komponento ali aktivne filtre. Aktivni filtri so lahko na omrežje priključeni paralelno ali serijsko. V doktorski disertaciji se bomo osredotočili na paralelno vezavo aktivnega filtra, saj aktivni filter neposredno vpliva na tokovno harmonsko popačenje pri tej vezavi, saj bo referenca aktivnega filtra temeljila na tokovnem porabniškem harmonskem viru. Kljub temu je lahko aktivni filter priključen na omrežje v več različnih kombinacijah s pasivno kompenzacijo. V doktorski disertaciji bomo analizirali tri kombinacije priključitve aktivnega filtra, in sicer paralelno in serijsko priključitev k pasivni kompenzaciji ter hibridno priključitev, kjer je aktivni filter priključen med tuljavo in kondenzatorjem. V osrednjem delu doktorske disertacije smo se osredotočili na novo kompenzacijsko funkcijo aktivnega filtra, ki je glavni izvirni prispevek k znanosti. V drugem, osrednjem delu doktorske disertacije je predstavljen razvoj kompenzacijske funkcije aktivnega filtra v različnih izvedbah kombinacij aktivnega in pasivnega dela, ki je drugi izvirni prispevek k znanosti. Na začetku osrednjega dela je pregled dosedanjih izvedb in načinov kompenzacije harmonskega popačenja, kjer smo ugotovili, da nobeden izmed algoritmov ne določa reference aktivnega filtra na podlagi prispevka porabnika k skupnemu popačenju. Harmonske razmere na priključnem mestu porabnika se spreminjajo z delovanjem aktivnega filtra, zato je treba določiti, kakšno je harmonsko popačenje, če aktivni filter ne deluje. Določanje tega harmonskega popačenja temelji na harmonskih impedancah ter izmerjenih vrednostih napetostnega in tokovnega harmonskega popačenja na priključnem mestu ter harmonskega toka aktivnega filtra. V nadaljevanju je natančno opisano določanje reference aktivnega filtra na podlagi prispevka porabnika k skupnemu harmonskemu popačenju. Določanje reference aktivnega filtra temelji na mešanem ekvivalentnem modelu, saj je omrežni del predstavljen kot napetostni harmonski vir oz. Theveninov model in porabniški del kot tokovni harmonski vir oz. Nortonov model. Aktivni filter kompenzira le porabniško emisijo tokovnega harmonskega popačenja na priključnem mestu, povzročenega zaradi tokovnega harmonskega vira porabnika. Porabniška emisija ne vključuje deleža toka na priključnem mestu, ki je povzročen z napetostnim harmonskim virom na omrežni strani. Delež toka na priključnem mestu, ki teče zaradi omrežnega napetostnega vira, imenujemo referenca toka omrežnega vira. Referenca toka omrežnega vira prikazuje tudi, koliko harmonskega toka lahko še teče na priključnem mestu porabnika. Referenca aktivnega filtra je delež harmonskega toka skozi omrežno impedanco, ki ga povzroči porabniški tokovni harmonski vir. Ker je referenca aktivnega filtra v vektorskem prostoru, je narejena projekcija njenega vektorja na vektor izmerjene vrednosti, saj tako lahko neposredno vpliva na izmerjeno vrednost tokovnega harmonskega popačenja. Referenca aktivnega filtra je implementirana v tri različne kombinacije aktivnega in pasivnega dela kompenzacije oz. filtra. Pri implementaciji reference aktivnega filtra so potrebne nekatere spremembe pri določanju parametrov in izračunu reference aktivnega filtra, saj vse vezave nimajo na voljo istih parametrov. Implementacija reference aktivnega filtra je tudi analizirana na nadomestnem modelu, ki pokaže delovanje aktivnega filtra v idealnem okolju. Pri paralelni kombinaciji pasivnega in aktivnega dela filtra je aktivni filter enostavno implementirati v že obstoječi postroj, saj se ga le dodatno priključi k pasivni kompenzaciji. Pri serijski kombinaciji je tok aktivnega filtra enak toku skozi pasivno kompenzacijo, zato je treba določanje reference aktivnega filtra ustrezno korigirati, saj je treba ločiti tok pasivnega in aktivnega dela kompenzacije. Pri hibridni kombinaciji aktivnega in pasivnega dela kompenzacije je treba izvesti še dodatne meritve napetosti, saj je aktivni filter med tuljavo in kondenzatorjem. V zadnjem delu doktorske disertacije so opisani rezultati analize in simulacij. Simulacije so bile izvedene v digitalnem programskem okolju PSCAD in z razvojno platformo DSP ter simulatorjem v realnem času. V digitalnem programskem okolju PSCAD je zmodelirano testno elektroenergetsko omrežje z dodanima aktivnima filtroma. Pri paralelni kombinaciji aktivne in pasivne kompenzacije je narejenih več simulacij. Rezultati pri prvem primeru pokažejo, da je treba kompenzirati celotni harmonski tok, saj je vzrok za harmonski tok v pasivni kompenzaciji brez dušilke in v nelinearnem bremenu. V drugem primeru sta narejeni simulaciji pri različni razglasitvi pasivne kompenzacije, saj v originalnem testnem omrežju porabnik zmanjšuje napetostno harmonsko popačenje. Rezultati s serijsko vezavo aktivnega dela k pasivni kompenzaciji so primerljivi z rezultati paralelne vezave aktivnega dela k pasivni kompenzaciji, saj se spremeni le upoštevanje pasivnega dela kompenzacije. V tem primeru so impedančne razmere podobne, zato so tudi rezultati med seboj primerljivi. Rezultati hibridne vezave aktivnega dela k pasivni kompenzaciji so nižji od rezultatov paralelne kombinacije za približno 4 % pri 11. in 13. harmonski komponenti, 14 % pri 7. harmonski komponenti in 30 % pri 5. harmonski komponenti. Tok aktivnega filtra je ojačan s pasivnim delom kompenzacije, kar je tudi razlog za zmanjšanje toka aktivnega filtra glede na preostali dve vezavi. Iz primerjave vseh rezultatov lahko sklepamo, da je referenca aktivnega dela pravilno določena. Pravilno delovanje reference aktivnega filtra je tudi potrjeno s primerjavo rezultatov analize in simulacij, saj so rezultati primerljivi. Pri upoštevanju predlagane reference aktivnega filtra je lahko harmonski tok aktivnega filtra zmanjšan od 5 do 40 % pri posamezni harmonski komponenti glede na kompenzacijo celotnega toka. Harmonski tok aktivnega filtra je lahko še dodatno zmanjšan z upoštevanjem napetostnega pogoja, kjer se ga lahko zmanjša tudi za več kot 80 %. Takšno zmanjšanje toka aktivnega filtra se zgodi v primerih razglašene kompenzacije, saj je treba v nasprotnem primeru kompenzirati celotno tokovno harmonsko popačenje, če ima porabnik kompenzacijo brez dušilke.

Jezik:Slovenski jezik
Ključne besede:aktivni filter, harmonsko popačenje, hibridne vezave aktivnega filtra, harmonske impedance, porabniški prispevek harmonskemu popačenju
Vrsta gradiva:Doktorsko delo/naloga
Organizacija:FE - Fakulteta za elektrotehniko
Leto izida:2022
PID:20.500.12556/RUL-137701 Povezava se odpre v novem oknu
COBISS.SI-ID:113041923 Povezava se odpre v novem oknu
Datum objave v RUL:28.06.2022
Število ogledov:932
Število prenosov:115
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:DEFINITION OF THE ACTIVE-FILTER COMPENSATION FUNCTION BASED ON CONSUMER CONTRIBUTION TO HARMONIC DISTORTION
Izvleček:
In today's electrical networks, power quality is important, as companies may not be able to provide adequate products when power quality decreases. Power quality is divided into several parameters, and one of them is voltage and harmonic distortion. New devices are daily installed in the electrical network, which causes harmonic distortion – they are either a harmonic distortion source or cause resonance with passive devices or compensation. Such devices are most often found in industrial consumers which have a higher-rated power and implemented reactive power compensation. Some already have an implemented active filter that compensates for harmonic distortion. In this case, only its algorithm can be updated with the newly proposed compensation function of the active filter, which determines its reference based on consumer’s contribution. The proposed compensatory function is also the main contribution to the findings of this PhD thesis. In the first part of the PhD thesis, we focus on an overview of the theoretical background. The overview includes a general description of harmonic distortion, vector representation of three-phase quantities, sources of harmonic distortion and determination of harmonic impedance. It also describes how harmonic distortion can be reduced by different approaches. In the electrical power system, odd harmonic components are mostly present, while even harmonic components are present only during transient phenomena. Odd harmonic components are divided into three characteristic groups, which are defined by the sequence of individual harmonic components: zero, negative and positive harmonic components. They are mostly determined by fast Fourier transformation, but other approaches are used for control algorithms, such as dq-transformation, which illustrates real-time quantities in the vector space at a given frequency. This frequency is determined by a harmonic component, as the vector space needs to be synchronized to the analyzed harmonic component. The DC value of this transformation presents values of the synchronized harmonic component and is determined by low-pass filters. Sources of harmonic distortion are also important in determining the consumer's contribution to total harmonic distortion. Harmonic distortion sources are divided into two major groups, namely commercial and industrial loads. Consumer loads mostly have lower power, and the consumer does not usually have built-in reactive power compensation. Industrial loads include larger three-phase power converters, arc furnaces and induction motors. In most cases, the consumer decides to compensate for reactive power if they have implemented devices with a higher power. In such cases, it is necessary to determine the location of the harmonic distortion source due to resonance amplification. Harmonic distortion can also be amplified by passive compensation of reactive power if it is not properly dimensioned or tuned. To properly determine the consumer’s contribution, it is necessary to determine harmonic impedances, separately for the network and the consumer. The determination of harmonic impedances in the PhD thesis will be based on reference impedances, as the actual harmonic impedances are practically impossible to determine in a real electrical environment. In most cases, it is necessary to reduce harmonic distortion, either because values defined by standards are exceeded or due to the provision of better-quality products. Harmonic distortion reduction can be done in several ways: by changing control algorithms of drives or passive compensators, or by active filters. Harmonic distortion is most commonly reduced using passive filters tuned to a specific harmonic component or active filters, but in the PhD thesis we will focus on active filters. Active filters can be connected to the network in parallel or in series. In the PhD thesis, we will focus on the parallel connection of active filters, since the active filter directly affects the current harmonic distortion in this connection because the reference of the active filter is based on the consumer’s current harmonic source. Nevertheless, the active filter can be connected to the mains in several different combinations with passive compensation. In the PhD thesis, we will analyze three combinations of active filter connection, namely parallel and serial connections to passive compensation and a hybrid connection, where the active filter is connected between the inductor and the capacitor. In the main part of the PhD thesis, we focus on the new compensation function of the active filter, which is the main original contribution to science. The second main part of the PhD thesis presents the development of the compensation function of the active filter in various combinations of active and passive parts, which is the second original contribution to science. At the beginning of the main part, we provide an overview of previous implementations and methods of harmonic distortion compensation, where we found that no algorithm determines the reference of the active filter based on the consumer's contribution to total distortion. Harmonic conditions at the consumer’s point of common coupling change with the operation of the active filter, so it is necessary to determine what harmonic distortion is like if the active filter does not work. The determination of this harmonic distortion is based on harmonic impedances, the measured values of voltage and current harmonic distortion at the point of common coupling as well as harmonic current of the active filter. The determination of the active filter reference based on the consumer's contribution to total harmonic distortion is detailed in the following part. Determining the active filter reference is based on a mixed equivalent model, as the network part is presented as a voltage harmonic source or Thevenin's model and the consumer’s part as a current harmonic source or Norton's model. The active filter compensates only for the consumer’s emission of harmonic distortion at point of common coupling due to the consumer’s harmonic source. Consumer’s emission does not include the share of the harmonic current caused by network voltage harmonic distortion on the network side, which is named reference of the network harmonic source. The reference of the network harmonic source also shows the volume of the harmonic current that still flows at the point of common coupling. The active filter reference is the share of the harmonic current running through the network impedance, caused by the consumer’s harmonic current source. Since the reference of the active filter is in the vector space, a projection of its vector on the vector of the measured value was made, as this can directly affect the measured value of the current harmonic distortion. The active filter reference is implemented in three different combinations of active and passive parts of the compensation or filter. When implementing the active filter reference, some changes are required in determining the parameters and calculating the active filter reference, as not all combinations have the same parameters available. The implementation of the active filter reference is also analysed based on the equivalent model, which presents how the active filter works under ideal conditions. With a parallel combination of passive and active parts of the filter, the active filter is easy to implement in an existing compensator, as it is only additionally connected to the passive compensation. In the series combination, the current of the active filter is equal to the current running through the passive compensation. Therefore, it is necessary to adjust the reference of the active filter appropriately, as the current of the passive and active parts of the compensation needs to be separated. In the hybrid combination of active and passive parts of the compensation, it is necessary to perform additional voltage measurements, as the active filter is between the inductor and the capacitor. The last part of the PhD thesis describes the results of the analysis and simulations. The simulations were performed in the digital programming environment with the PSCAD software, the DSP development platform and a real-time simulator. In the PSCAD software environment, a test power network with added active filters was modelled. In a parallel combination of active and passive compensation, several simulations were made. The results of example 1 show that it is necessary to compensate the total harmonic current, as the harmonic current is the result of detuned passive compensation and nonlinear load. In example 2, simulations were made at different tuning values of passive compensation, since the consumer reduces the voltage harmonic distortion in the original test network. The results with the series connection of the active part to the passive compensation are comparable with the results of parallel connection of active part to the passive compensation because it only changes the consideration of the passive part of the compensation. In this case, the impedance characteristics are similar and this is the reason why the results are comparable. The results of the hybrid connection of the active part to the passive compensation are reduced comparing to the results of the parallel combination for 4 % at 11th and 13th harmonic component, 14 % at 7th harmonic component and 30 % at 5th harmonic component. The active filter current is amplified by the passive part of the compensator and this is the reason for reduction of the required active filter current compared to the other two connections. From the comparison of the results, it can be concluded that the reference of the active part is correctly determined. The proper operation of the active filter reference is also confirmed with the comparison of the analysis and simulation results because the results are comparable. Using the suggested active filter reference, the harmonic current of the active filter could be decreased by 5% to 40% at a separate harmonic component based on total current compensation. The active filter harmonic current could be additionally decreased applying the voltage condition, which could decrease the harmonic current by over 80%. In case of such decrease in the harmonic current, a correctly detuned passive compensator must be installed, otherwise the consumer needs to compensate total harmonic current at the point of common coupling.

Ključne besede:active filter, harmonic distortion, hybrid active filter connections, harmonic impedance, consumer’s contribution to harmonic distortion