Analiza natančnosti cervikalne zapore ogrodja, izdelanega po različnih tehnologijah : diplomsko delo
Fijavž, Žan
(
Author
),
Rojko, Franc
(
Mentor
)
More about this mentor...
,
Levec, Tina
(
Reviewer
)
PDF - Presentation file,
Download
(4,57 MB)
Abstract
Uvod: V literaturi lahko najdemo množico obrazložitev, kaj je natančnost in kaj kakovost. Glede na izsledke raziskav in znanstvena dognanja je mogoče trditi, da je natančen izdelek v večini primerov tudi kakovosten. Kakovost je doseganje vseh lastnosti izdelka ali storitve, ki jih kupec pričakuje. Ker vse tehnologije stremijo h klinično sprejemljivim izdelkom, se nenehno izboljšujejo in med seboj tekmujejo. V diplomskem delu smo raziskovali natančnost izdelave cervikalne zapore ogrodja, izdelanega po različnih tehnologijah. Namen: Namen diplomskega dela je teoretično in slikovno predstaviti različne tehnologije izdelave ogrodja ter predstaviti metode in načine analiziranja točnosti matematično definiranega modela CAD, ki smo ga zasnovali. Metode dela: Pri teoretičnem delu diplomskega dela je metoda deskriptivna, praktični del pa temelji na analizi natančnosti cervikalne zapore ogrodja, izdelanega po različnih tehnologijah. Rezultati: Dobljene rezultate posameznih sklopov meritev smo ovrednotili z negativnimi točkami. Glede na dobljene rezultate je najmanj negativnih točk prejelo rezkanje, sledili sta tehnologiji SLM in SLA. Razprava in zaključek: Analiza natančnosti cervikalne zapore ogrodja, po različnih tehnologijah primerjava metod SLA, SLM in rezkanja, je pokazala, da je najnatančnejša izdelava z rezkanjem. Ta metoda je v strojništvu zelo razvita, drugi dve pa sta mlajši.
Language:
Slovenian
Keywords:
diplomska dela
,
laboratorijska zobna protetika
,
CAD/CAM
,
dodajalne tehnologije
,
rezkanje
Work type:
Bachelor thesis/paper (mb11)
Tipology:
2.11 - Undergraduate Thesis
Organization:
ZF - University College of Health Studies
Year:
2020
Publisher:
[Ž. Fijavž]
Number of pages:
49 str., [16] str. pril
UDC:
616.31
COBISS.SI-ID:
27697667
Views:
108
Downloads:
67
Metadata:
Average score:
(0 votes)
Your score:
Voting is allowed only to
logged in
users.
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Share:
AddThis uses cookies that require your consent.
Edit consent...
Secondary language
Language:
English
Title:
Accuracy analysis of marginal fit of the framework, fabricated by different technologies : diploma work
Abstract:
Introduction: According to the literature there are many explanations of what accuracy and quality is. Based on scientific research it can be argued that an accurate product is in most cases also of a good quality. In short, quality is the achievement of all the features of a product or service that the customer expects. As all technologies strive for clinically acceptable products, they are constantly improving and competing against each other. In the diploma work we had researched and analysed the accuracy of the marginal fit and other parameters of the framework performed by different technologies. Purpose: The purpose of the diploma work is to theoretically and visually present different technologies for the manufacture of framework and to present methods and ways of analysing the accuracy of the mathematically defined CAD model that we have designed. Methods: A descriptive method was used in theoretical part of the diploma work. The practical part is based on the analysis of marginal fit of framework performed by different technologies. Results: The obtained results of individual sets of measurements were evaluated with negative points. Thus, based on the results obtained, we can say that the technology which received the least negative points was milling followed by SLM and SLA. Discussion and conclusion: Accuracy analysis of marginal fit of framework fabricated by different technologies compared to SLA, SLM and milling methods showed that the most accurate manufacturing is milling. The latter technology is very developed in the field of mechanical engineering and the other two are younger.
Keywords:
diploma theses
,
laboratory dental prosthetics
,
CAD / CAM
,
additive technologies
,
milling