Izvleček
V okviru diplomskega dela na Fakulteti za kemijo in kemijsko tehnologijo, Univerze v Ljubljani, je bil vpeljan sistem za anionsko izmenjevalno kromatografijo s konduktometrično detekcijo. S sistemom so bile izvedene analize realnih vzorcev v katerih smo določali: fluoridne, kloridne, nitritne, bromidne, nitratne, fosfatne in sulfatne ione. Metoda ionske kromatografije je bila tudi delno validirana, saj smo študirali linearnost ter določili LOD in LOQ. Določali smo primernost oz. vpliv kromatografskih pogojev kot so: pretok in sestava, pH ter starost eluenta. Eksperimentalno delo je vključevalo tudi regeneracijo kolone, s katero smo želeli doseči manjšo asimetričnost vrhov, ustrezno ločitev vrhov, ki pripadata fosfatnim in sulfatnim ionom ter odpraviti zamike retencijskih časov.
Jezik:
Slovenski jezik
Ključne besede:
ionska kromatografija
,
anioni
,
validacija
,
regeneracija kolone
Vrsta gradiva:
Diplomsko delo/naloga
Tipologija:
2.11 - Diplomsko delo
Organizacija:
FKKT - Fakulteta za kemijo in kemijsko tehnologijo
Leto izida:
2019
PID:
20.500.12556/RUL-109665
COBISS.SI-ID:
1538327747
Datum objave v RUL:
06.09.2019
Število ogledov:
4767
Število prenosov:
770
Metapodatki:
Citiraj gradivo
Navadno besedilo
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
TOMŠIČ, Rok, 2019,
IONSKA KROMATOGRAFIJA ZA DOLOČEVANJE ANIONOV
[na spletu]. Diplomsko delo. [Dostopano 14 julij 2025]. Pridobljeno s: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=slv&id=109665
Kopiraj citat
Objavi na:
Sekundarni jezik
Jezik:
Angleški jezik
Izvleček:
As a part of the diploma thesis at the Faculty of Chemistry and Chemical Technology of the University of Ljubljana, an anion exchange chromatography system with conductometric detection was introduced. The system performed analyses of real samples in which we determined: fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulphate ions. The ion chromatography method was also partially validated, as we studied linearity and determined LOD and LOQ. We determined the suitability or the influence of the chromatographic conditions such as: flow and composition, pH and age of the eluent. The experimental work also included the regeneration of the column, which was aimed at reducing the peak asymmetry of the peaks, the proper separation of the peaks belonging to the phosphate and sulphate ions, and to eliminate the retention time delays.
Ključne besede:
ion chromatography
,
anions
,
validation
,
column regeneration
Podobna dela
Podobna dela v RUL:
Variabilne optične uklonske mrežice na osnovi polimerov in tekočih kristalov
Sestava in umerjanje astronomskega spektrografa na AGO Golovec
Phase changes in molybdenum oxides induced by AFM tip and laser excitation
Determination of magnesium in food supplements
Magnetic bottle electron spectroscopy of atomic reactions triggered by a pulsed electron beam
Podobna dela v drugih slovenskih zbirkah:
Optical properties of plastically deformed copper
Določitev kovin v tleh z atomsko absorpcijsko spektroskopijo
Determination of antimicrobical efficiency of medical textiles
Diffraction gratings formed by bent-core liquid crystals in the twist-bend nematic phase
Predicting chemical composition of forage using NIR spectroscopy
Nazaj