Abstract
Diplomsko delo obravnava tematiko kalibracije absorpcijskih klešč za namen določitve kleščnega faktorja. V teoretičnem delu je sprva pojasnjeno, zakaj je potrebno testiranje elektromagnetne kompatibilnosti, kako se elektromagnetne motnje širijo v okolje in s katerimi pristopi omogočimo napravam doseganje želene elektromagnetne kompatibilnosti. V nadaljevanju sledi prikaz zgradbe absorpcijskih klešč in opredelitev njihovih zmogljivostnih parametrov. V naslednjem poglavju je podrobno opisan standard za kalibracijo absorpcijskih klešč, nato pa še dve kalibracijski metodi, in sicer originalna metoda in metoda z vpenjalom (angl. jig method). Predstavljene so tudi razlike med njima ter prednosti in slabosti obeh. Delo se nadaljuje s samo kalibracijo klešč in načini meritve posameznih parametrov. Opisane so tudi negotovosti, ki prispevajo k rezultatu meritev. Na koncu je predstavljen vpliv razmakov na rezultat meritev.

Language:Slovenian
Keywords:EMC, EMI, absorpcijske klešče, kalibracija
Work type:Bachelor thesis/paper
Organization:FE - Faculty of Electrical Engineering
Year:2018
PID:20.500.12556/RUL-104827 This link opens in a new window
Publication date in RUL:12.10.2018
Views:1636
Downloads:401
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Evaluation of absorbing clamps for EMC testing
Abstract:
The thesis deals with calibration of absorbing clamps. In the theoretical part, it first outlines the basics of electromagnetic compatibility, explaining why it is required, how electromagnetic interference spreads to the environment, and which approaches can be used to ensure electromagnetic compatibility. Next, the thesis describes the structure of absorbing clamps and their performance parameters. It also presents the standard for calibration of absorbing clamps, which is then described in detail in the next section. Here two calibration methods are described, the original method and the jig method. The differences between the two methods are presented, along with the advantages and disadvantages of each method. The thesis continues with the calibration of absorbing clamps and the methods for measuring individual parameters. The uncertainties that contribute to the results of the measurements are also described. In the last chapter, the importance of the distance between measurement equipment and its effect on the measurement are presented tested.

Keywords:EMC, EMI, absorbing clamp, calibration

Similar documents