izpis_h1_title_alt

Spiralni prenosnik toplote v gospodinjskih aparatih
ID Bahovec, Janez (Author), ID Kitanovski, Andrej (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (6,02 MB)
MD5: 491627159CA9312EB353210E6618DC78

Abstract
V diplomski nalogi smo analizirali prihranke električne energije v pomivalnem stroju z vgradnjo prenosnika toplote. Zaradi neizkoriščene toplote odpadne vode v pomivalnem stroju imamo večjo rabo električne energije. Te izgube je mogoče delno povrniti z uporabo prenosnika toplote. Izbrana je bila najbolj ustrezna vrsta prenosnika toplote. Na zasnovanem spiralnem prenosniku toplote so bile izvedene simulacije v programu Fluent. Prenosnik toplote je bil izdelan na podlagi rezultatov simulacij. S pomočjo izvedenih meritev prihranka električne energije smo analizirali učinek vgradnje prenosnika toplote za potrebe rekuperacije. Ugotovili smo, da z uporabo spiralnega prenosnika toplote pri enem pranju prihranimo 12,57% električne energije v primerjavi s klasičnim pomivalnim strojem.

Language:Slovenian
Keywords:prenos toplote pomivalni stroj energijska učinkovitost rekuperacija toplote odpadna toplota
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Publisher:[J. Bahovec]
Year:2018
PID:20.500.12556/RUL-102616 This link opens in a new window
UDC:621.56:620.9(043.2)
COBISS.SI-ID:16399131 This link opens in a new window
Publication date in RUL:05.09.2018
Views:3146
Downloads:254
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Spiral heat exchanger in household appliances
Abstract:
This thesis explores electricity savings in a dishwasher with the installation of a heat exchanger. Due to unused waste water in the dishwasher, we have higher electricity consumption. These losescan be partially recovered using a heat exchanger. The most suitable type of heat exchanger was selected. Simulations in the Fluent program were carried out on the designed spiral heat exchanger. Based on the results of the simulations, the heat exchanger was manufactured. Using the performed measurements of electricity savings we analyzed the effect of installation of a heat exchanger for the needs of recovery. It was found that with the use of a spiral heat exchanger in one washing energy saving would save 12.57% of the electricity compared to a conventional dishwasher.

Keywords:Heat transfer Dishwasher Energy efficiency Heat recovery Waste heat

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back