izpis_h1_title_alt

Optimizacija zaskočnega mehanizma za pozicioniranje palice na tripodni kontroli dostopa
ID Glavan, Žan (Avtor), ID Klemenc, Jernej (Mentor) Več o mentorju... Povezava se odpre v novem oknu

.pdfPDF - Predstavitvena datoteka, prenos (3,49 MB)
MD5: 76E060BCF63A8BE4C5E1298C9FB40728

Izvleček
Pri snovanju mehanizma tripodne kontrole dostopa smo se soočili z dvema problemoma. Treba je bilo določiti primerno silo za solenoidni aktivator in preveriti potencialno kritične napetosti v revolverju. Do rezultatov smo prišli z analitičnim izračunom in numeričnimi simulacijami. S preskusom prototipa smo validirali izračune in potrdili končno obliko mehanizma palice in zaskočke. Izračuni in simulacije so pokazali ustreznost drugega koncepta, pri katerem bo potrebna dodatna obdelava stične površine med zaskočko in palico, saj je treba zagotoviti koeficient trenja, ki je manjši ali enak 0,2.

Jezik:Slovenski jezik
Ključne besede:tripodna kontrola dostopa, numerična simulacija, solenoidni aktivator, zaskočka, statični preračun
Vrsta gradiva:Zaključna naloga
Tipologija:2.11 - Diplomsko delo
Organizacija:FS - Fakulteta za strojništvo
Kraj izida:Ljubljana
Založnik:[Ž. Glavan]
Leto izida:2018
Št. strani:X, 24 str.
PID:20.500.12556/RUL-102247 Povezava se odpre v novem oknu
UDK:004.942:519.876.5(043.2)
COBISS.SI-ID:16166427 Povezava se odpre v novem oknu
Datum objave v RUL:27.07.2018
Število ogledov:1226
Število prenosov:369
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Sekundarni jezik

Jezik:Angleški jezik
Naslov:Optimizing the lacking mechanism for positioning the bars to tripod access control device
Izvleček:
In the process of designing a mechanism of a tripod access control device we were confronted with two problems. First, it was required to determine the appropriate force for the solenoid actuator as well as search for any potential critical tension in the revolver. We obtained the results by using an analitical calculation and numerical simulations. As a result of conducting the prototype tests our calculations were verified and the final design of the mechanism bars and ratchet was confirmed. However, the calculations and simulations exhibited a better suitability of the second concept that does not require an additional approach regarding the contact surface treatment of the bars and ratchet, for the desired friction coeficient to be smaller than or equal 0,2.

Ključne besede:tripod access control device, numerical simulation, solenoid actuator, ratchet, static calculation

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj