Your browser does not allow JavaScript!
JavaScript is necessary for the proper functioning of this website. Please enable JavaScript or use a modern browser.
Repository of the University of Ljubljana
Open Science Slovenia
Open Science
DiKUL
slv
|
eng
Search
Browse
New in RUL
About RUL
In numbers
Help
Sign in
Details
Projekt hiše z leseno okvirno nosilno konstrukcijo : magistrsko delo
ID
Bajc, Klemen
(
Author
),
ID
Saje, Drago
(
Mentor
)
More about this mentor...
,
ID
Ber, Boštjan
(
Comentor
)
PDF - Presentation file,
Download
(6,59 MB)
MD5: F8804DEEA2D1EDA744798744A0BEA107
PID:
20.500.12556/rul/d101d518-b616-4aad-b4cb-181bfe026a25
PDF - Appendix,
Download
(8,04 MB)
MD5: E1743F1895624C81A7625EBB5E16BE36
PID:
20.500.12556/rul/6515cf96-ab1c-4307-baef-3e01c29a9dc0
PDF - Appendix,
Download
(1,25 MB)
MD5: 393C0DAE8A57F96FEEFBF8D71EBB09DC
PID:
20.500.12556/rul/f76c476b-6fa8-4205-8eea-f54ab2ee9452
Image galllery
Abstract
V magistrskem delu smo obravnavali različne konstrukcijske sisteme lesenih stavb. Predstavili smo posamezne sisteme in opisali prenos vertikalnih in horizontalnih sil. Za izbran nosilni sistem smo izdelali statično in dinamično analizo. Obravnavali smo enodružinsko stanovanjsko hišo. Na podlagi idejne zasnove smo se odločili za okvirno nosilno konstrukcijo. Zasnovali smo jo iz pretežno lesenih elementov, nekaj pa je jeklenih. Vertikalna obremenitev se prenaša preko členkasto povezanih gred in stebrov, horizontalna obremenitev pa preko lesenega in jeklenega povezja. Statično in dinamično analizo modela nosilne konstrukcije smo izvedli s pomočjo programske opreme Scia Engineer. Statične vplive smo določili na podlagi veljavnih standardov SIST EN 1991-1:2004. Prereze elementov nosilne konstrukcije smo dimenzionirali za merodajno obremenitev po metodi mejnih stanj nosilnosti in mejnih stanj uporabnosti. Obremenitev zaradi potresne obtežbe smo določili z uporabno modalne analize. Nosilnosti elementov smo preverili na potresno obremenitev. Dimenzionirali smo pomembnejše spoje, izvedene s pomočjo jeklene pločevine, ki elemente povezuje med seboj. Izrisali smo pozicijske načrte.
Language:
Slovenian
Keywords:
lesena gradnja
,
okvirna nosilna konstrukcija
,
statična analiza
,
potresna obtežba
,
dimenzioniranje konstrukcije
,
dimenzioniranje spojev
Work type:
Master's thesis/paper
Typology:
2.09 - Master's Thesis
Organization:
FGG - Faculty of Civil and Geodetic Engineering
Publisher:
[K. Bajc]
Year:
2017
PID:
20.500.12556/RUL-97417
UDC:
624.011.1:624.042.7(497.4)(043.3)
COBISS.SI-ID:
8213857
Publication date in RUL:
25.10.2017
Views:
4590
Downloads:
1521
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
BAJC, Klemen, 2017,
Projekt hiše z leseno okvirno nosilno konstrukcijo : magistrsko delo
[online]. Master’s thesis. K. Bajc. [Accessed 4 April 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=97417
Copy citation
Share:
Secondary language
Language:
English
Title:
Project of House with Timber Loadbearing Frame Structure : Master thesis
Abstract:
Various types of timber loadbearing construction were analyzed in this master’s thesis. All of the systems were described individually and the transfer of vertical and horizontal load was shown. Static and dynamic analysis was performed on a single-family detached house for the selected loadbearing system. Regarding the conceptual design a heavy timber frame was selected as the type of loadbearing construction. The timber frame was designed using mainly timber and some steel elements. Vertical loads are transferred through rotationally joined columns and beams, while horizontal loads are transferred through timber and steel bracing. The static and dynamic loadbearing analysis was performed using Scia Engineer software. The load was analysed according to the valid SIST EN 1991-1:2004 standard. The relavant strain on the timber and steel was checked for both the ultimate limit and the serviceability limit state. Seismic load was calculated using modal analysis. Checks of individual construction elements were once again made for seismic load combinations. Design and check of significant joint was performed. Most of them were designed using a steel plate, which connects the elements together. Drawings were made of the assembly.
Keywords:
timber construction
,
timber frame structure
,
static analysis
,
seismic load
,
joint design
Similar documents
Similar works from RUL:
Sistematični pregled izsledkov raziskav o vlogi vitamina D pri COVID-19
Robust saliva-based RNA extraction-free one-step nucleic acid amplification test for mass SARS-CoV-2 monitoring
SARS-CoV-2 virions or ubiquitous cell structures?
Viral and host genetic and epigenetic biomarkers related to SARS-CoV-2 cell entry, infection rate, and disease severity
Similar works from other Slovenian collections:
Pulmonary pathology and COVID-19
Covid-19
Vpliv epidemije Sars-Cov-2 (COVID-19) na zaznano kakovost življenja
ARIA-EAACI statement on asthma and COVID-19 (June 2, 2020)
Podatki COVID-19 sledilnika
Back