Abstract
Pri zagotavljanju življenjske dobe izdelka igra tesnost vgradnih delov veliko vlogo. Za zagotavljanje tesnosti je potrebno razviti ustrezno merilno metodo. V delu so predstavljene štiri merilne metode za preskušanje tesnosti po metodi s sledilnim plinom. Na obravnavanih statorjih smo opravili meritve preskušanja tesnosti. Na podlagi rezultatov smo vrednotili merilne metode in izbrali najbolj primerno za kasnejšo izvedbo kontrole v proizvodnji. Za izbrano merilno metodo smo predlagali tudi potrebne izboljšave. Locirali smo najbolj pogosta mesta netesnosti statorja.

Language:Slovenian
Keywords:puščanje masna spektrometrija merilna metoda stator sledilni plin
Work type:Bachelor thesis/paper
Organization:FS - Faculty of Mechanical Engineering
Year:2017
PID:20.500.12556/RUL-95490 This link opens in a new window
Publication date in RUL:20.09.2017
Views:10352
Downloads:508
Metadata:XML DC-XML DC-RDF
:
DEMŠAR, Janez, 2017, Preskušanje tesnosti po metodi s sledilnim plinom [online]. Bachelor’s thesis. [Accessed 22 July 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=95490
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Leak testing using a tracer gas method
Abstract:
At ensuring product's lifetime, tightness plays a crucial part. To ensure tightness an appropriate measuring method must be developed. This paper presents four measuring methods for leak testing using a tracer gas. We performed leak tests on the considered stators. On the basis of the results, we evaluated the measuring methods and chose the most suitable for later control in production. We proposed most necessary improvements for the chosen method. We also located the most common sites of stator leakage.

Keywords:leakage mass spectrometry measuring method stator tracer gas

Similar documents

Similar works from RUL:
  1. Granzyme B translocates across the lipid membrane only in the presence of lytic agents
  2. Trans-membrane area asymmetry controls the shape of cellular organelles
  3. Targeted lipid analysis of haemolytic mycelial extracts of Aspergillus niger
  4. Characterisation of perfringolysin O mutants with substitutions in cholesterol-recognition site
  5. Characterisation of the amino acid substitutions in cholesterol-binding domain of perfringolysin O
Similar works from other Slovenian collections:
  1. Design of protein logic gate system operating on lipid membranes
  2. Vloga okužb pri limfomih in levkemijah
  3. Response of biomembrane domains to external stimuli
  4. Hypoxia influences the cellular cross-talk of human dermal fibroblasts
  5. Rapid UPLC-ESI-MS/MS based assay for discovery of UDP-N-acetylmuramoyl-L-alanine:D-glutamate (MurD) ligase inhibitors