izpis_h1_title_alt

Primerjava in ovrednotenje izotropnega in anizotropnega modela sončnega obsevanja
ID Mekuč, Miha (Author), ID Prek, Matjaž (Mentor) More about this mentor... This link opens in a new window, ID Butala, Vincenc (Comentor)

.pdfPDF - Presentation file, Download (6,24 MB)
MD5: 688CC774020CCA73AB7033879AD3CEC0
PID: 20.500.12556/rul/e81487c7-7a39-4dce-a6d9-cb498347c7a0

Abstract
Za dimenzioniranje solarnih naprav in preračunavanje rabe energije v stavbah potrebujemo podatke o jakostih sevanja in obsevanja različno nagnjenih in usmerjenih ploskev. Izmerjeni podatki so na razpolago samo za vodoravne ploskve. Za drugače nagnjene in usmerjene ploskve moramo podatke preračunati. Raziskovalci so razvili več modelov, ki se v grobem ločijo na izotropne in anizotropne. Najbolj popularna modela sta Liu-Jordanov med izotropnimi in Perezov med anizotropnimi. V zadnjem času anizotropni modeli zamenjujejo izotropne modele. V tem delu je izvedena primerjava izračunanih in izmerjenih vrednosti za različno nagnjene in usmerjene ploskve. S primerjavo izračunanih vrednosti po več modelih in izmerjenih vrednosti je ovrednoten in potrjen smisel prehoda in izboljšanje zaradi prehoda na Perezov anizotropni model. Preračunan je tudi vpliv zamenjave modela na prestop sevanja skozi zastekljeno okno. Ugotovljeno in pokazano je, da Perezov anizotropni model daje bolj zanesljive in tehnično uporabne rezultate. Kot praktični primer je izveden preračun sončnega sevanja za zimski vrt, ki bo zgrajen na južni strani stanovanjske stavbe.

Language:Slovenian
Keywords:sevanje, obsevanje, sončno, model, izotropni, anizotropni, okno
Work type:Master's thesis/paper
Organization:FS - Faculty of Mechanical Engineering
Year:2017
PID:20.500.12556/RUL-94858 This link opens in a new window
Publication date in RUL:08.09.2017
Views:1390
Downloads:475
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Isotropic and anisotropic solar model comparison and evaluation
Abstract:
To design solar equipment and calculate energy performance of buildings solar radiation and irradiation to inclined and diferent oriented surfaces are needed. Measured data exist for horizontal surfaces only. For inclined and diferent oriented surfaces values have to be calculated. Researchers developed many models, which can be divided into two groups: isotropic and anisotropic. Most popular isotropic and anisotropic model are Liu-Jordan and Perez respectively. In several times isotropic models are replaced by anisotropic. In this work calculations and measurements for vertical and inclined surfaces with different orientations were compared. Sense and improvement of calculations due to change to Perez anisotropic model are evaluated with comparison of with some models calculated and measured data. It is confirmed, that change to Perez anisotropic model is reasonable. Transmission of radiation through the glass window was recalculated too to evaluate model change impact. It is found out that, Perez anisotropic model gives more reliable and technical usefull results. As real example, impact of solar radiation on energy performance of greenhouse built at south side of dwelling house, is evaluated.

Keywords:radiation, irradiation, solar, model, isotropic, anisotropic, window