izpis_h1_title_alt

Modalno posodabljanje s pomočjo hitre kamere
ID Zaletelj, Klemen (Author), ID Slavič, Janko (Mentor) More about this mentor... This link opens in a new window, ID Boltežar, Miha (Comentor)

.pdfPDF - Presentation file, Download (7,39 MB)
MD5: 36095F6189A77896F51D2697D4D7B55B
PID: 20.500.12556/rul/ffbc8b45-6736-42b7-97c5-7c32ddfb0ac4

Abstract
Modalno posodabljanje z uporabo pospeškomerov je relativno dobro raziskano, a je merjenje velikega števila prostostnih stopenj lahko zamudno in včasih nemogoče. Hitra kamera omogoča merjenje velikega števila prostostnih stopenj hkrati, zato je tak pristop primeren za uporabo v postopku posodabljanja. Predstavili smo teoretično ozadje uveljavljenih metod za posodabljanje in njihovo delovanje prikazali na numeričnih primerih. Za prikaz postopkov na realnih problemih smo izvedli eksperiment v laboratoriju. Rezultati so pokazali, da je posodabljanje s pomočjo hitre kamere učinkovito in primerljivo s klasičnim pristopom pri posodabljanju manjšega števila parametrov.

Language:Slovenian
Keywords:modalno posodabljanje, hitra kamera, strukturna dinamika, optični tok, iterativne metode, direktne metode
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Publisher:[K. Zaletelj]
Year:2017
PID:20.500.12556/RUL-94847 This link opens in a new window
UDC:531.776(043.2)
COBISS.SI-ID:15693083 This link opens in a new window
Publication date in RUL:08.09.2017
Views:2581
Downloads:785
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:High-speed camera modal updating
Abstract:
Modal updating using accelerometers is relatively well researched, however measuring large numbers of degrees of freedom can be time consuming and sometimes impossible. With the use of high-speed cameras, it is possible to measure those large amounts of coordinates simultaniously. This fact makes the approach appropriate for use in modal updating. In the first sections, the theoretical background of well-established methods is presented and their use is demonstrated on numerical examples. Use of updating methods on more realistic examples is shown on experiment carried out in laboratory. The high-speed camera approach was found to be effective and comparable with classical approach, when applied to small number of updating parameters.

Keywords:modal updating, high-speed camera, structural dynamics, optical flow, iterative methods, direct methods